General considerations for optimizing a capillary electrophoresis-electrospray ionization time-of-flight mass spectrometry system

被引:23
作者
Lazar, IM
Lee, ED
Rockwood, AL
Lee, ML [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Eyring Sci Ctr 225, Provo, UT 84602 USA
[2] Sensar Corp, Provo, UT 84601 USA
关键词
capillary electrophoresis mass spectrometry; optimization; instrumentation; paraquat; gramicidin S; enkephalins;
D O I
10.1016/S0021-9673(98)00743-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modern analytical instrumentation must be able to perform rapid, reliable, and sensitive analysis. The on-line combination of analytical techniques such as capillary electrophoresis (CE), electrospray ionization (ESI) and mass spectrometry (MS) can provide solutions to numerous problems related to complex mixtures of organic/inorganic, or biological materials. Optimum performance of complex instrumentation such as this can be achieved only if each individual component operates with maximum proficiency, and is in full harmony/compatibility with the other components. The present paper reports on the evaluation and optimization of a CE-ESI time-of-flight mass spectrometry (TOF-MS) system. The main features of the instrument are speed and sensitivity. Low amol (3-11) detection Limits have been achieved with continuous infusion experiments, and the acquisition rate can be as high as 10 000 spectra s(-1). For CE-TOF-MS, minimum detection was in the very-low fmol (1-10) range. The major contributing factors to high quality analysis characteristic to each separate technique are considered, relevant examples are discussed, and fast, and sensitive analysis is demonstrated. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:279 / 288
页数:10
相关论文
共 38 条
[1]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[2]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[3]  
BANKS JF, 1995, J CHROMATOGR A, V712, P245
[4]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[5]   CAPILLARY ZONE ELECTROPHORESIS OF 2 CATIONIC HERBICIDES, PARAQUAT AND DIQUAT [J].
CAI, JY ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1193-1200
[6]   CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
CAI, JY ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :667-692
[7]   Laser vaporization/ionization interface for capillary electrophoresis time-of-flight mass spectrometry [J].
Chang, SY ;
Yeung, ES .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2251-2257
[8]   TRAPPING, DETECTION, AND MASS DETERMINATION OF COLIPHAGE T4 DNA IONS OF 10(8) DA BY ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, RD ;
CHENG, XH ;
MITCHELL, DW ;
HOFSTADLER, SA ;
WU, QY ;
ROCKWOOD, AL ;
SHERMAN, MG ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1995, 67 (07) :1159-1163
[9]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[10]   COLLISIONAL FOCUSING EFFECTS IN RADIO-FREQUENCY QUADRUPOLES [J].
DOUGLAS, DJ ;
FRENCH, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :398-408