Surface plasmon resonance immunosensor for detection of Legionella pneumophila

被引:20
作者
Oh, BK [1 ]
Lee, W [1 ]
Bae, YM [1 ]
Lee, WH [1 ]
Choi, JW [1 ]
机构
[1] Sogang Univ, Dept Chem Engn, Seoul 100611, South Korea
关键词
immunosensor; surface plasmon resonance; protein G; self-assembly technique; Legionella pneumophila;
D O I
10.1007/BF02940266
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An immunosensor based on surface plasmon resonance (SPR) onto a protein G layer by self-assembly technique was developed for detection of Legionella pneumophila. The protein G layer by self-assembly technique! was fabricated on a gold (Au) surface by adsorbing the 11 mercaptoundecanoic acid (MUA) and an activation process for the chemical binding of the free amine (-NH2) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDAC) in series. The formation of the protein G layer by self-assembly technique on the Au substrate and the binding of the antibody and antigen in series were confirmed by SPIR spectroscopy. The surface topographies of the fabricated thin films on an Au substrate were also analyzed by using an atomic force microscope (AFM). Consequently, an immunosensor for the detection of L. pneumophila using SPR was developed with a detection limit of up to 10(2) CFU per mL.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 24 条
[1]   BACTERIAL FC-RECEPTORS [J].
BOYLE, MDP ;
REIS, KJ .
BIO-TECHNOLOGY, 1987, 5 (07) :697-703
[2]   Design and self-assembly of open, regular, 3D mesostructures [J].
Breen, TL ;
Tien, J ;
Oliver, SRJ ;
Hadzic, T ;
Whitesides, GM .
SCIENCE, 1999, 284 (5416) :948-951
[3]  
Choi JW, 2001, J MICROBIOL BIOTECHN, V11, P979
[4]  
DARREN MD, 1998, BIOSENS BIOELECTRON, V13, P1213
[5]   BIOSPECIFIC INTERACTION ANALYSIS USING SURFACE-PLASMON RESONANCE DETECTION APPLIED TO KINETIC, BINDING-SITE AND CONCENTRATION ANALYSIS [J].
FAGERSTAM, LG ;
FROSTELLKARLSSON, A ;
KARLSSON, R ;
PERSSON, B ;
RONNBERG, I .
JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2) :397-410
[6]   Study on highly sensitive potentiometric IgG immunosensor [J].
Feng, CL ;
Xu, YH ;
Song, LM .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) :190-192
[7]   Description of a single modular optical setup for ellipsometry, surface plasmons, waveguide modes, and their corresponding imaging techniques including Brewster angle microscopy [J].
Harke, M ;
Teppner, R ;
Schulz, O ;
Motschmann, H ;
Orendi, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (08) :3130-3134
[8]   VIABLE LEGIONELLA-PNEUMOPHILA NOT DETECTABLE BY CULTURE ON AGAR MEDIA [J].
HUSSONG, D ;
COLWELL, RR ;
OBRIEN, M ;
WEISS, E ;
PEARSON, AD ;
WEINER, RM ;
BURGE, WD .
BIO-TECHNOLOGY, 1987, 5 (09) :947-950
[9]  
Joklik WK, 1992, ZINSSER MICROBIOLOGY
[10]  
Kim JW, 1999, J SCI FOOD AGR, V79, P1513, DOI 10.1002/(SICI)1097-0010(199908)79:11&lt