Ultra-High-Pressure RPLC Hyphenated to an LTQ-Orbitrap Velos Reveals a Linear Relation between Peak Capacity and Number of Identified Peptides

被引:114
作者
Koecher, Thomas [1 ]
Swart, Remco
Mechtler, Karl
机构
[1] Res Inst Mol Pathol IMP, Vienna, Austria
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; SHOTGUN PROTEOMICS; PROTEIN; SEPARATIONS; OPTIMIZATION; RATES;
D O I
10.1021/ac103243t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Currently, unbiased protein identification is mostly performed by directly coupling reversed-phase liquid chromatography (RPLC) via electrospray ionization to a mass spectrometer. In contrast to the innovations in mass spectrometric instrumentation, cutting-edge technology in RPLC has generally not been well adopted. Here, we describe the effects of increased peak capacities on the number of identified proteins and peptides in complex mixtures utilizing collision-induced dissociation on an LTQ-Orbitrap Velos, providing a rationale for using advanced RPLC technology in LC-MS/MS. Using two different column lengths and gradient times between 1 and 10 h, we found a linear relation between the obtained peak capacities and the number of identified peptides. We identified on average 2516 proteins in the tryptic digest of 1 mu g of HeLa lysate using an 8 h gradient on a 50 cm column packed with 2 mu m C18 reversed-phase chromatographic. material.
引用
收藏
页码:2699 / 2704
页数:6
相关论文
共 32 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]   MaxQuant enables high peptide identification rates, individualized p.p.b.-range mass accuracies and proteome-wide protein quantification [J].
Cox, Juergen ;
Mann, Matthias .
NATURE BIOTECHNOLOGY, 2008, 26 (12) :1367-1372
[3]  
DAVIS JE, 1983, ANAL CHEM, V55, pR202
[4]   Direct proteomic mapping of the lung microvascular endothelial cell surface in vivo and in cell culture [J].
Durr, E ;
Yu, JY ;
Krasinska, KM ;
Carver, LA ;
Yates, JR ;
Testa, JE ;
Oh, P ;
Schnitzer, JE .
NATURE BIOTECHNOLOGY, 2004, 22 (08) :985-992
[5]   High-efficiency liquid chromatography-mass spectrometry separations with 50 mm, 250 mm, and 1 m long polymer-based monolithic capillary columns for the characterization of complex proteolytic digests [J].
Eeltink, Sebastiaan ;
Dolman, Sebastiaan ;
Detobel, Frederik ;
Swart, Remco ;
Ursem, Mario ;
Schoenmakers, Peter J. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (43) :6610-6615
[6]   Correlation between peak capacity and protein sequence coverage in proteomics analysis by liquid chromatography-mass spectrometry/mass spectrometry [J].
Fairchild, Jacob N. ;
Walworth, Matthew J. ;
Horvath, Krisztian ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (29) :4779-4783
[7]   Multidimensional separations-based shotgun proteomics [J].
Fournier, Marjorie L. ;
Gilmore, Joshua M. ;
Martin-Brown, Skylar A. ;
Washburn, Michael P. .
CHEMICAL REVIEWS, 2007, 107 (08) :3654-3686
[8]   Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography [J].
Gilar, M ;
Daly, AE ;
Kele, M ;
Neue, UD ;
Gebler, JC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :183-192
[9]   Tandem affinity purification of functional TAP-tagged proteins from human cells [J].
Gregan, Juraj ;
Riedel, Christian G. ;
Petronczki, Mark ;
Cipak, Lubos ;
Rumpf, Cornelia ;
Poser, Ina ;
Buchholz, Frank ;
Mechtler, Karl ;
Nasmyth, Kim .
NATURE PROTOCOLS, 2007, 2 (05) :1145-1151
[10]   False Discovery Rates of Protein Identifications: A Strike against the Two-Peptide Rule [J].
Gupta, Nitin ;
Pevzner, Pavel A. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (09) :4173-4181