Correlation between peak capacity and protein sequence coverage in proteomics analysis by liquid chromatography-mass spectrometry/mass spectrometry

被引:19
作者
Fairchild, Jacob N. [1 ]
Walworth, Matthew J. [1 ]
Horvath, Krisztian [1 ,2 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Univ Pannonia, Dept Analyt Chem, H-8200 Veszprem, Hungary
关键词
Liquid chromatography-mass; spectrometry/mass spectrometry; Proteomics; Peptides; Peptide digest; BSA; Shell particles; Gradient elution; SPECTRAL DATA; OFF-LINE; SEPARATION; PERFORMANCE; MIXTURES; ONLINE;
D O I
10.1016/j.chroma.2010.05.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) allows the acquisition of a vast amount of analytical data in the aim of identifying peptides and proteins. Difficulties arise when attempting to identify proteins from the results of analyses of their peptide digests. We investigated possible quantitative correlations between the peak capacity achieved in chromatographic analyses and the protein sequence coverage. For this purpose, we used high performance liquid chromatography (HPLC) columns packed with fully and superficially porous (shell) particles of average sizes ranging from 2.6 to 15 mu m in diameter. We found that the sequence coverage of bovine serum albumin obtained with a 10-min gradient elution run on a column packed with 2.6 mu m shell particles is greater than that provided by 40-min gradients run on columns packed with 15 or 10 mu m particles and equal to those yielded by the same 40-min gradient run on columns packed with 3 and 5 mu m particles. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:4779 / 4783
页数:5
相关论文
共 26 条
[1]  
Aston FW, 1919, P CAMB PHILOS SOC, V19, P300
[2]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[3]   Approaches to comprehensive multidimensional liquid chromatography systems [J].
Fairchild, Jacob N. ;
Horvath, Krisztian ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) :1363-1371
[4]   Theoretical advantages and drawbacks of on-line, multidimensional liquid chromatography using multiple columns operated in parallel [J].
Fairchild, Jacob N. ;
Horvath, Krisztian ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (34) :6210-6217
[5]   Analysis of complex protein mixtures with improved sequence coverage using (CE-MS/MS)n [J].
Garza, Selynda ;
Moini, Mehdi .
ANALYTICAL CHEMISTRY, 2006, 78 (20) :7309-7316
[7]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&
[8]   Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography [J].
Gilar, M ;
Daly, AE ;
Kele, M ;
Neue, UD ;
Gebler, JC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :183-192
[9]   Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (10) :1604-1615
[10]   Performance of columns packed with the new shell particles, Kinetex-C18 [J].
Gritti, Fabrice ;
Leonardis, Irene ;
Shock, David ;
Stevenson, Paul ;
Shalliker, Andrew ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (10) :1589-1603