A 384-well solid-phase extraction for LC/MS/MS determination of methotrexate and its 7-hydroxy metabolite in human urine and plasma

被引:63
作者
Rule, G [1 ]
Chapple, M [1 ]
Henion, J [1 ]
机构
[1] Adv BioAnalyt Serv, Ithaca, NY 14850 USA
关键词
D O I
10.1021/ac000897i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-phase extraction procedure, in a 384-well format, has been developed for methotrexate and its primary metabolite, 7-hydroxymethotrexate, in human urine and plasma. This format has not been utilized previously for solid-phase extraction of drugs from biological fluids, The 384-well plates contained a C-18 stationary phase bonded to silica particles which are incorporated into a glass-fiber membrane. Methotrexate and 7-hydroxymethotrexate have been quantified across the curve range of 1 to 50 mug/mL and 50 to 1000 ng/mL, respectively, in urine and from 5 to 250 ng/mL and 5 to 100 ng/mL, respectively, in plasma. Both analytes are quantified by linear regression using 20-muL sample aliquots. Experiments to evaluate the influence of particle size, elution volume, and injection volume on signal intensity were conducted and are reported, along with the results of experiments examining cross contamination between wells. Recovery was determined to be greater than or equal to 95% from urine. Results from a run of 384 samples analyzed over a 14-h period indicate that 384-well SPE can be successfully utilized to increase analytical run sizes and sample throughput for LC/MS/MS determination of small drug molecules in biological samples.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 20 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]   Automated protein precipitation by filtration in the 96-well format [J].
Biddlecombe, RA ;
Pleasance, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 734 (02) :257-265
[4]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[5]  
2-S
[6]  
BOUVIER ESP, 1998, CURR TRENDS DEV SA S, pS53
[7]   Ultra-high throughput screen of two-million-member combinatorial compound collection in a miniaturized, 1536-well assay format [J].
Dunn, D ;
Orlowski, M ;
McCoy, P ;
Gastgeb, F ;
Appell, K ;
Ozgur, L ;
Webb, M ;
Burbaum, J .
JOURNAL OF BIOMOLECULAR SCREENING, 2000, 5 (03) :177-187
[8]  
Janiszewski J, 1997, RAPID COMMUN MASS SP, V11, P1033
[9]   High-throughput method development approaches for bioanalytical mass spectrometry [J].
Janiszewski, JS ;
Swyden, MC ;
Fouda, HG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2000, 38 (06) :255-258
[10]   Rapid, solid phase extraction technique for the high-throughput assay of darifenacin in human plasma [J].
Kaye, B ;
Herron, WJ ;
Macrae, PV ;
Robinson, S ;
Stopher, DA ;
Venn, RF ;
Wild, W .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1658-1660