High-throughput method development approaches for bioanalytical mass spectrometry

被引:13
作者
Janiszewski, JS [1 ]
Swyden, MC [1 ]
Fouda, HG [1 ]
机构
[1] Pfizer Inc, Div Cent Res, Groton, CT 06340 USA
关键词
D O I
10.1093/chromsci/38.6.255
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rational approach to the development and optimization of solid-phase extraction (SPE) methods is described. The semiautomated scheme allows for the simultaneous testing of multiple chemistries using a custom multiple-sorbent 96-well method development plate. Optimized extraction conditions for up to five analytes are determined in a single 2.5-h experiment. The experiment can be tailored to determine SPE conditions (including wash protocols) for related analytes. Data obtained by liquid chromatography-atmospheric pressure ionization-mass spectrometry allows the quantitation of absolute recovery and selection of the best extraction conditions for approximately 100 analytes of diverse structure. Optimized extraction protocols yielding at least 80% recovery are determined for 81% of the analytes. For 96% of the analytes screened, extraction conditions resulting in recoveries of ≥ 60% are determined. The most generic set of SPE conditions consist of either C8 or C18 sorbent with an eluent composition of acetonitrile with 5mM nitric acid added.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 11 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]  
[Anonymous], SORBENT EXTRACTION T
[4]   Determination of the glucocorticoid fluticasone propionate in plasma by automated solid-phase extraction and liquid chromatography tandem mass spectrometry [J].
Callejas, SL ;
Biddlecombe, RA ;
Jones, AE ;
Joyce, KB ;
Pereira, AI ;
Pleasance, S .
JOURNAL OF CHROMATOGRAPHY B, 1998, 718 (02) :243-250
[5]   High-throughput solid-phase extraction for the determination of cimetidine in human plasma [J].
Hempenius, J ;
Wieling, J ;
Brakenhoff, JPG ;
Maris, FA ;
Jonkman, JHG .
JOURNAL OF CHROMATOGRAPHY B, 1998, 714 (02) :361-368
[6]  
Janiszewski J, 1997, RAPID COMMUN MASS SP, V11, P1033
[7]   Rapid, solid phase extraction technique for the high-throughput assay of darifenacin in human plasma [J].
Kaye, B ;
Herron, WJ ;
Macrae, PV ;
Robinson, S ;
Stopher, DA ;
Venn, RF ;
Wild, W .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1658-1660
[8]   Design and evaluation of an automated solid-phase extraction method development system for use with biological fluids [J].
Parker, TD ;
Wright, DS ;
Rossi, DT .
ANALYTICAL CHEMISTRY, 1996, 68 (14) :2437-2441
[9]   SELECTIVITY AT THE SOLID-LIQUID INTERFACE ON BONDED SORBENTS [J].
SCHUNK, TC ;
BURKE, MF .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1986, 25 (1-3) :81-103
[10]  
Simpson H, 1998, RAPID COMMUN MASS SP, V12, P75, DOI 10.1002/(SICI)1097-0231(19980131)12:2<75::AID-RCM112>3.0.CO