Diffuse optical tomography of cerebral blood flow, oxygenation, and metabolism in rat during focal ischemia

被引:316
作者
Culver, JP
Durduran, T
Furuya, T
Cheung, C
Greenberg, JH
Yodh, AG
机构
[1] Univ Penn, Cerebrovasc Res Ctr, Dept Phys & Astron, Philadelphia, PA 19104 USA
[2] Univ Penn, Cerebrovasc Res Ctr, Dept Neurol, Philadelphia, PA 19104 USA
关键词
diffuse optical tomography; ischemia; cerebral blood flow; laser Doppler flowmetry; tissue oxygen saturation; cerebral metabolic rate of oxygen consumption;
D O I
10.1097/01.WCB.0000076703.71231.BB
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Diffuse optical tomography (DOT) is an attractive approach for evaluating stroke physiology. It provides hemodynamic and metabolic imaging with unique potential for continuous noninvasive bedside imaging in humans. To date there have been few quantitative spatial-temporal studies of stroke pathophysiology based on diffuse optical signatures. The authors report DOT images of hemodynamic and metabolic contrasts using a rat middle cerebral artery occlusion (MCAO) stroke model. This study used a novel DOT device that concurrently obtains coregistered images of relative cerebral blood volume (rCBV), tissue-averaged hemoglobin oxygen saturation (Sto(2)), and relative cerebral blood flow (rCBF). The authors demonstrate how these hemodynamic measures can be synthesized to calculate an index of the oxygen extraction fraction (OEF) and the cerebral metabolic rate of oxygen consumption (CMRo(2)). Temporary (60-minute) MCAO was pet-formed on five rats. Ischemic changes, averaged over the 60 minutes of occlusion, were as follows: rCBF = 0.42 +/- 0.04, rCBV = 1.02 0.04, DeltaSto(2) = -11 +/- 2%, rOEF = 1.39 +/- 0.06 and rCMRo(2) 0.59 +/- 0.07. Although rOEF increased in response to decreased blood flow, rCMRo(2) decreased. The sensitivity of this method of DOT analysis is discussed in terms of assumptions about baseline physiology, and the diffuse optical results are compared with positron emission tomography, magnetic resonance imaging, and histology observations in the literature.
引用
收藏
页码:911 / 924
页数:14
相关论文
共 73 条
  • [1] Gender-linked brain injury in experimental stroke
    Alkayed, NJ
    Harukuni, I
    Kimes, AS
    London, ED
    Traystman, RJ
    Hurn, PD
    [J]. STROKE, 1998, 29 (01) : 159 - 165
  • [2] Dynamic changes in cerebral blood flow, O2 tension, and calculated cerebral metabolic rate of O2 during functional activation using oxygen phosphorescence quenching
    Ances, BM
    Wilson, DF
    Greenberg, JH
    Detre, JA
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2001, 21 (05) : 511 - 516
  • [3] MRI-guided optical tomography: Prospects and computation for a new imaging method
    Barbour, RL
    Graber, HL
    Chang, JW
    Barbour, SLS
    Koo, PC
    Aronson, R
    [J]. IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04): : 63 - 77
  • [4] Noninvasive functional imaging of human brain using light
    Benaron, DA
    Hintz, SR
    Villringer, A
    Boas, D
    Kleinschmidt, A
    Frahm, J
    Hirth, C
    Obrig, H
    van Houten, JC
    Kermit, EL
    Cheong, WF
    Stevenson, DK
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (03) : 469 - 477
  • [5] SCATTERING AND IMAGING WITH DIFFUSING TEMPORAL FIELD CORRELATIONS
    BOAS, DA
    CAMPBELL, LE
    YODH, AG
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (09) : 1855 - 1858
  • [6] Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head
    Boas, DA
    Culver, JP
    Stott, JJ
    Dunn, AK
    [J]. OPTICS EXPRESS, 2002, 10 (03): : 159 - 170
  • [7] The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics
    Boas, DA
    Gaudette, T
    Strangman, G
    Cheng, XF
    Marota, JJA
    Mandeville, JB
    [J]. NEUROIMAGE, 2001, 13 (01) : 76 - 90
  • [8] Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation
    Boas, DA
    Yodh, AG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (01): : 192 - 215
  • [9] Systematic diffuse optical image errors resulting from uncertainty in the background optical properties
    Cheng, XF
    Boas, DA
    [J]. OPTICS EXPRESS, 1999, 4 (08): : 299 - 307
  • [10] In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies
    Cheung, C
    Culver, JP
    Takahashi, K
    Greenberg, JH
    Yodh, AG
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) : 2053 - 2065