Myocardial bridging: Depiction rate and morphology at CT coronary angiography - Comparison with conventional coronary angiography

被引:75
作者
Leschka, Sebastian [1 ]
Koepfli, Pascal [3 ]
Husmann, Lars [1 ]
Plass, Andre [2 ]
Vachenauer, Robert [2 ]
Gaemperli, Oliver [3 ]
Schepis, Tiziano [3 ]
Genoni, Michele [2 ]
Marincek, Borut [1 ]
Eberli, Franz R. [3 ]
Kaufmann, Philipp A. [3 ,4 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Univ Zurich, Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
D O I
10.1148/radiol.2463062071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively assess the depiction rate and morphologic features of myocardinal (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. Materials and Methods: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for, which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64- mid conventional coronary anoography. Fifty additional patients (19 women, 31 men ; mean age, 59.2 years +/- 13.2) who underwent. CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. Results: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment, length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients its was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P <.001). With CT, a significant correlation was not found between systolic compression and length (r = 016, P = .25, n = 150) but was found with depth (r = 0.65, P <.01, n = 150) of the tunneled segment. In 14, patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P <.001, P <.01, and P <.001, respectively). Conclusion: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 27 条
[1]   Myocardial bridging [J].
Alegria, JR ;
Herrmann, J ;
Holmes, DR ;
Lerman, A ;
Rihal, CS .
EUROPEAN HEART JOURNAL, 2005, 26 (12) :1159-1168
[2]   Myocardial bridging on left anterior descending coronary artery evaluated by multidetector computed tomography [J].
Amoroso, G ;
Battolla, L ;
Gemignani, C ;
Panconi, M ;
Petronio, AS ;
Rondine, P ;
Mariani, M ;
Falaschi, F .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 (2-3) :335-337
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   MYOCARDIAL BRIDGING OF CORONARY-ARTERIES ASSOCIATED WITH AN IMPENDING ACUTE MYOCARDIAL-INFARCTION [J].
BESTETTI, RB ;
FINZI, LA ;
AMARAL, FTV ;
SECCHES, AL ;
OLIVEIRA, JSM .
CLINICAL CARDIOLOGY, 1987, 10 (02) :129-131
[5]  
BESTETTI RB, 1989, CHEST, V95, P706, DOI 10.1378/chest.95.3.706-b
[6]   Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - Comparison with conventional invasive angiography [J].
Ehara, M ;
Surmely, JF ;
Kawai, M ;
Katoh, O ;
Matsubara, T ;
Terashima, M ;
Tsuchikane, E ;
Kinoshita, Y ;
Suzuki, T ;
Ito, T ;
Takeda, Y ;
Nasu, K ;
Tanaka, N ;
Murata, A ;
Suzuki, Y ;
Sato, K ;
Suzuki, T .
CIRCULATION JOURNAL, 2006, 70 (05) :564-571
[7]  
FERREIRA AG, 1991, BRIT HEART J, V66, P364
[8]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[9]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810
[10]   Myocardial bridging - Noninvasive diagnosis with multidetector CT [J].
Goitein, O ;
Lacomis, JM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (02) :238-240