Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry

被引:43
作者
Clowers, Brian H. [1 ]
Belov, Mikhail E. [1 ]
Prior, David C. [1 ]
Danielson, William F., III [1 ]
Ibrahim, Yehia [1 ]
Smith, Richard D. [1 ]
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
关键词
D O I
10.1021/ac7022712
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to the inherently low duty cycle of ion mobility spectrometry (IMS) experiments that sample from continuous ion sources, a range of experimental advances have been developed to maximize ion utilization efficiency. The use of ion trapping and accumulation approaches prior to the ion mobility drift tube has demonstrated significant gains over discrete sampling from continuous sources but have traditionally relied upon a signal averaging (SA) to attain analytically useful signal-to-noise ratios (SNR). Multiplexed (MP) techniques based upon the Hadamard transform offer an alternative experimental approach by which ion utilization efficiency can be elevated from similar to 1 to similar to 50%. Recently, our research group demonstrated a unique multiplexed ion mobility time-of-flight (MP-IMS-TOF) approach that incorporates ion trapping and can extend ion utilization efficiency beyond 50%. However, the spectral reconstruction of the multiplexed signal using this experiment approach requires the use of sample-specific weighting designs. Such general weighting designs have been shown to significantly enhance ion utilization efficiency using this MP technique, but cannot be universally applied. By modifying both the ion trapping and the pseudorandom sequence (PRS) used for the MP experiment, we have eliminated the need for complex weighting matrices. For both simple and complex mixtures, SNR enhancements of up to 13 were routinely observed as compared to the SA-IMS-TOF approach. In addition, this new class of PRS provides a 2-fold enhancement in the number of ion gate pulses per unit time compared to the traditional HT-IMS experiment.
引用
收藏
页码:2464 / 2473
页数:10
相关论文
共 50 条
[1]  
Asbury GR, 2000, TALANTA, V50, P1291
[2]  
Asbury GR, 2000, J MICROCOLUMN SEP, V12, P172, DOI 10.1002/(SICI)1520-667X(2000)12:3<172::AID-MCS7>3.0.CO
[3]  
2-W
[4]   Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures [J].
Baker, Erin Shammel ;
Clowers, Brian H. ;
Li, Fumin ;
Tang, Keqi ;
Tolmachev, Aleksey V. ;
Prior, David C. ;
Belov, Mikhail E. ;
Smith, Richard D. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (07) :1176-1187
[5]   Multiplexed ion mobility spectrometry-orthogonal time-of-flight mass spectrometry [J].
Belov, Mikhail E. ;
Buschbach, Michael A. ;
Prior, David C. ;
Tang, Keqi ;
Smith, Richard D. .
ANALYTICAL CHEMISTRY, 2007, 79 (06) :2451-2462
[6]   Amyloid β-protein:: Monomer structure and early aggregation states of Aβ42 and its Pro19 alloform [J].
Bernstein, SL ;
Wyttenbach, T ;
Baumketner, A ;
Shea, JE ;
Bitan, G ;
Teplow, DB ;
Bowers, MT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (07) :2075-2084
[7]   Fourier transform electrospray ion mobility spectrometry [J].
Chen, YH ;
Siems, WF ;
Hill, HH .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :75-84
[8]   Hadamard transform ion mobility spectrometry [J].
Clowers, BH ;
Siems, WF ;
Hill, HH ;
Massick, SM .
ANALYTICAL CHEMISTRY, 2006, 78 (01) :44-51
[9]   Separation of sodiated isobaric disaccharides and trisaccharides using electrospray ionization-atmospheric pressure ion mobility-time of flight mass spectrometry [J].
Clowers, BH ;
Dwivedi, P ;
Steiner, WE ;
Hill, HH ;
Bendiak, B .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (05) :660-669
[10]   Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry [J].
Clowers, Brian H. ;
Ibrahim, Yehia M. ;
Prior, David C. ;
Danielson, William F., III ;
Belov, Mikhail E. ;
Smith, Richard D. .
ANALYTICAL CHEMISTRY, 2008, 80 (03) :612-623