Detection of Escherichia coli in potable water using indirect impedance technology

被引:20
作者
Timms, S [1 ]
Colquhoun, KO [1 ]
Fricker, CR [1 ]
机构
[1] THAMES WATER UTIL LTD,SPECER HOUSE LABS,READING RG2 0JN,BERKS,ENGLAND
关键词
Escherichia coli; water; indirect impedance;
D O I
10.1016/0167-7012(96)00903-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An indirect impedance technique using membrane lauryl sulphate broth has been developed and compared with a defined substrate medium (Colilert, IDEXX) for the detection of Escherichia coli in water. Indirect impedance gave a 93.3% agreement with Colilert(R) (MPN) with a detection time for the complete development of the Escherichia coli growth signal of 15 h to detect a single Escherichia coli which is quicker than either conventional membrane filtration (minimum 42 h) and currently available defined substrate media(18-24 h). The indirect impedance MLSB method was screened against a range of other bacterial species associated with water and only two bacteria (Salmonella arizonae and Salmonella poona) gave strong signals, both distinguishable from that associated with Escherichia coli. Potentially, indirect impedance offers some advantages over currently available technologies for the detection of Escherichia coli in water and food samples. With the impedance method the need for confirmation is removed, it was also found to be more rapid than Colilert(R) and it is possible for the method to be used with samples containing high solids/low volume where membrane filtration would be inappropriate.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 1994, MICROBIOLOGY WATER 1
[2]   INFLUENCE OF ENVIRONMENTAL STRESS ON ENUMERATION OF INDICATOR BACTERIA FROM NATURAL-WATERS [J].
BISSONNETTE, GK ;
JEZESKI, JJ ;
MCFETERS, GA ;
STUART, DG .
APPLIED MICROBIOLOGY, 1975, 29 (02) :186-194
[3]   AN INVESTIGATION OF INDIRECT CONDUCTIMETRY FOR DETECTION OF SOME FOOD-BORNE BACTERIA [J].
BOLTON, FJ .
JOURNAL OF APPLIED BACTERIOLOGY, 1990, 69 (05) :655-661
[4]  
BUTLER JN, 1982, CO2 EQUILIBRIA THEIR
[5]   DETECTION OF ESCHERICHIA-COLI IN POTABLE WATER USING DIRECT IMPEDANCE TECHNOLOGY [J].
COLQUHOUN, KO ;
TIMMS, S ;
FRICKER, CR .
JOURNAL OF APPLIED BACTERIOLOGY, 1995, 79 (06) :635-639
[6]   A PRELIMINARY-STUDY OF THE USE OF COLILERT FOR WATER-QUALITY MONITORING [J].
COWBURN, JK ;
GOODALL, T ;
FRICKER, EJ ;
WALTER, KS ;
FRICKER, CR .
LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) :50-52
[7]   SURVIVAL AND GROWTH-CHARACTERISTICS OF ESCHERICHIA-COLI ASSOCIATED WITH HEMORRHAGIC COLITIS [J].
DOYLE, MP ;
SCHOENI, JL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (04) :855-856
[8]  
DRUGGAN P, 1993, SOC APPL BACTERIOLOG, V31
[9]  
FRICKER CR, 1994, P 1993 WAT QUAL TECH, P525
[10]   APPLICATION OF THE POLYMERASE CHAIN-REACTION TO THE IDENTIFICATION OF ESCHERICHIA-COLI AND COLIFORMS IN WATER [J].
FRICKER, EJ ;
FRICKER, CR .
LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) :44-46