A novel technique for identification of Doppler microembolic signals based on the coincidence method - In vitro and in vivo evaluation

被引:40
作者
Georgiadis, D
Goeke, J
Hill, M
Konig, M
Nabavi, DG
Stogbauer, F
Zunker, P
Ringelstein, EB
机构
[1] UNIV MUNSTER,DEPT NEUROL,W-4400 MUNSTER,GERMANY
[2] TECH UNIV COLOGNE,COLOGNE,GERMANY
关键词
diagnostic imaging; Doppler; embolism;
D O I
10.1161/01.STR.27.4.683
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The applicability of a novel differentiation technique in embolus detection based on the coincidence principle and using a multigate probe was evaluated in this study. Methods According to the coincidence method, high-intensity transients should only be classified as microembolic signals if they appear sequentially in the two sample volumes monitored and within a defined time window calculated from the blood velocity and the spatial distance between the insonation depths. Part A: microbubbles were introduced in a continuous flow bench model of the middle cerebral artery to evaluate the accuracy of the multigate probe in embolus detection. Part B: in the subjects and patients, the minimal and maximum time delays in the appearance of microembolic signals in the two middle cerebral artery sample volumes were calculated as 0.01 second and set at 0.1 second, respectively. The multigate probe was used to monitor (1) 5 normal volunteers in whom 1008 artifact signals were produced, (2) 2 patients undergoing aortic valve replacement surgery, and (3) 12 patients with potential cardiac or carotid embolic sources. Results In the bench model, 95.5% of microembolic signals produced by microbubbles appeared in the two sample volumes with a time delay between 0.02 and 0.05 second, while in the remaining 4.5% a shorter passage time of 0.01 second was measured. A total of 1968 high-intensity signals were recorded in subjects and patients. All but 20 of these (99%) appeared in both monitoring channels within the above time frame. To summarize, 996 (98.8%) of the 1004 artifact signals and 943 (98.1%) of the 961 microembolic signals were correctly classified. Conclusions Application of the coincidence theory to distinguish microembolic signals from artifacts provides a promising new technique with high sensitivity and specificity that could decisively improve the validity of embolus detection.
引用
收藏
页码:683 / 686
页数:4
相关论文
共 9 条
[1]  
BOTHE W, 1929, Z PHYS, V29, P751
[2]  
BRUCHER R, 1993, STROKE, V24, P510
[3]   PREVALENCE AND CHARACTERISTICS OF INTRACRANIAL MICROEMBOLI SIGNALS IN PATIENTS WITH DIFFERENT TYPES OF PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
GROSSET, DG ;
KELMAN, A ;
FAICHNEY, A ;
LEES, KR .
STROKE, 1994, 25 (03) :587-592
[4]  
HOCKS APG, 1981, IEEE T SON ULTRASON, V28, P242
[5]   COMPUTERIZED DETECTION OF CEREBRAL EMBOLI AND DISCRIMINATION FROM ARTIFACT USING DOPPLER ULTRASOUND [J].
MARKUS, H ;
LOH, A ;
BROWN, MM .
STROKE, 1993, 24 (11) :1667-1672
[6]   TRANSCRANIAL DOPPLER SONOGRAPHY - ANATOMICAL LANDMARKS AND NORMAL VELOCITY VALUES [J].
RINGELSTEIN, EB ;
KAHLSCHEUER, B ;
NIGGEMEYER, E ;
OTIS, SM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :745-761
[7]   REAL-TIME IDENTIFICATION OF CEREBRAL MICROEMBOLI WITH US FEATURE DETECTION BY A NEURAL-NETWORK [J].
SIEBLER, M ;
ROSE, G ;
SITZER, M ;
BENDER, A ;
STEINMETZ, H .
RADIOLOGY, 1994, 192 (03) :739-742
[8]   PROCESSING DOPPLER ULTRASOUND SIGNALS FROM BLOOD-BORNE EMBOLI [J].
SMITH, JL ;
EVANS, DH ;
FAN, L ;
THRUSH, AJ ;
NAYLOR, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (05) :455-462
[9]  
Spencer MP, 1992, TRANSCRANIAL DOPPLER, P215