PREVALENCE AND CHARACTERISTICS OF INTRACRANIAL MICROEMBOLI SIGNALS IN PATIENTS WITH DIFFERENT TYPES OF PROSTHETIC CARDIAC VALVES

被引:122
作者
GEORGIADIS, D
GROSSET, DG
KELMAN, A
FAICHNEY, A
LEES, KR
机构
[1] UNIV GLASGOW,WESTERN INFIRM,DEPT CARDIAC SURG,GLASGOW G11 6NT,SCOTLAND
[2] UNIV GLASGOW,WESTERN INFIRM,DEPT MED,GLASGOW,SCOTLAND
关键词
EMBOLISM; HEART VALVE PROSTHESIS; ULTRASONICS;
D O I
10.1161/01.STR.25.3.587
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in three groups of patients with different prosthetic valves. Methods One hundred seventy-nine patients with prosthetic cardiac valves (85 Bjork-Shiley, 56 Medtronic-Hall, and 38 Carpentier-Edwards) and 25 normal subjects were examined using transcranial Doppler. Monitoring time was 30 minutes over the right middle cerebral artery. Results The prevalence and numbers of embolic signals were significantly higher in patients with Bjork-Shiley compared with those with Medtronic-Hall and Carpentier-Edwards valves (89% versus 50% and 53%, respectively; P<.001, chi(2); 156 [112, 204] versus 2 [1, 4] and 2 [1, 4] singals/h, respectively; median [95% nonparametric confidence interval], both P<.001, multiple comparisons, Bonferroni correction). The signal intensity was significantly higher in patients with Bjork-Shiley and Medtronic-Hall valves than patients with Carpentier-Edwards valves (2435 [2345, 2527] and 2120 [1745, 2483] versus 225 [184, 287] power units, median [95% confidence interval], both P<.001). No correlation was found between embolic signal numbers and clinical parameters including history of neurological deficit, cardiac rhythm, duration of artificial valve, previous cardiac operations, or intensity of anticoagulation. Embolic signals were not detected in any of the control subjects. Conclusions Our data showed that the prevalence, quantity, and acoustic characteristics of Doppler embolic signals differ in patients having three different types of prosthetic heart valves. However, no correlation with clinical parameters was identified.
引用
收藏
页码:587 / 592
页数:6
相关论文
共 28 条
  • [1] TRANSCRANIAL DOPPLER SONOGRAPHY - EXAMINATION TECHNIQUE AND NORMAL REFERENCE VALUES
    ARNOLDS, BJ
    VONREUTERN, GM
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (02) : 115 - 123
  • [2] A PROSPECTIVE EVALUATION OF THE BJORK-SHILEY, HANCOCK, AND CARPENTIER-EDWARDS HEART-VALVE PROSTHESES
    BLOOMFIELD, P
    KITCHIN, AH
    WHEATLEY, DJ
    WALBAUM, PR
    LUTZ, W
    MILLER, HC
    [J]. CIRCULATION, 1986, 73 (06) : 1213 - 1222
  • [3] BRUCHER R, 1993, STROKE, V24, P510
  • [4] CORTINA JM, 1986, J THORAC CARDIOV SUR, V91, P174
  • [5] FUSTER V, 1982, CIRCULATION, V66, P157
  • [6] THROMBOEMBOLISM IN PATIENTS WITH PROSTHETIC HEART-VALVES - AN ADEQUATELY CONTROLLED INTENSE ANTICOAGULANT-THERAPY AND ITS INFLUENCE ON THE OCCURRENCE OF THROMBOEMBOLISM IN RELATION TO VALVE TYPE
    GOSSINGER, H
    NIESSNER, H
    GRUBECK, B
    MOSSLACHER, H
    BETTELHEIM, P
    LECHNER, K
    MLCZOCH, J
    DOMANIG, E
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1986, 34 (05) : 283 - 286
  • [7] CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES
    GRAF, T
    FISCHER, H
    REUL, H
    RAU, G
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) : 169 - 174
  • [8] QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE
    GROSSET, DG
    GEORGIADIS, D
    KELMAN, AW
    LEES, KR
    [J]. STROKE, 1993, 24 (12) : 1922 - 1924
  • [9] DETECTION OF MIDDLE CEREBRAL EMBOLI DURING CORONARY-ARTERY BYPASS-SURGERY USING TRANSCRANIAL DOPPLER SONOGRAPHY
    HARRISON, MJG
    PUGSLEY, W
    NEWMAN, S
    PASCHALIS, C
    KLINGER, L
    TREASURE, T
    ASPEY, B
    [J]. STROKE, 1990, 21 (10) : 1512 - 1512
  • [10] THE EFFECT OF GAS EMBOLI ON RABBIT CEREBRAL BLOOD-FLOW
    HELPS, SC
    PARSONS, DW
    REILLY, PL
    GORMAN, DF
    [J]. STROKE, 1990, 21 (01) : 94 - 99