A rapid and sensitive LC/MS/MS assay for quantitative determination of digoxin in rat plasma

被引:68
作者
Yao, M [1 ]
Zhang, HJ [1 ]
Chong, SH [1 ]
Zhu, MS [1 ]
Morrison, RA [1 ]
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Dept Metab & Pharmacokinet, Princeton, NJ 08543 USA
关键词
pharmacokinetic; digoxin; rats;
D O I
10.1016/S0731-7085(03)00050-5
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Digoxin is a cardiac glycoside that is widely used for the treatment of congestive heart failure. To evaluate pharmacokinetics of digoxin in rats, a sensitive LC/MS/MS assay was developed and validated for the determination of digoxin concentration in rat plasma. For detection, a Sciex API3000 LC/MS/MS with atmospheric pressure ionization (API) mass spectrometry turbo ion spray inlet in the positive ion-multiple reaction monitoring mode was used to monitor precursor-->product ions of m/z 798.6-->4651.6 for digoxin and m/z 577.6-->433.3 for oleandrin, the internal standard (IS). The standard curve was linear (r(2)greater than or equal to0.999) over the digoxin concentration range of 0.1-100 ng/ml in plasma for digoxin. The mean predicted concentrations of the quality control samples deviated by < 5.8% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8.6% relative standard deviation. At the lower limit of quantitation (LLQ) of 0.1 ng/ml, the mean deviation of predicted concentrations from the nominal value was within 3.7%. The extraction recoveries of digoxin and internal standard were 82.7+/-3.9 and 105.9+/-2.3%, respectively. The present method was successfully applied to characterization of pharmacokinetic profiles of digoxin in rats after oral administration. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1189 / 1197
页数:9
相关论文
共 13 条
[1]
Cobbe SM, 1997, EUR HEART J, V18, pC33
[2]
THE MDR1 GENE-PRODUCT, P-GLYCOPROTEIN, MEDIATES THE TRANSPORT OF THE CARDIAC GLYCOSIDE, DIGOXIN [J].
DELANNOY, IAM ;
SILVERMAN, M .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1992, 189 (01) :551-557
[3]
The role of intestinal P-glycoprotein in the interaction of digoxin and rifampin [J].
Greiner, B ;
Eichelbaum, M ;
Fritz, P ;
Kreichgauer, HP ;
Von Richter, O ;
Zundler, J ;
Kroemer, HK .
JOURNAL OF CLINICAL INVESTIGATION, 1999, 104 (02) :147-153
[4]
HORI R, 1993, J PHARMACOL EXP THER, V266, P1620
[5]
P-GLYCOPROTEIN-MEDIATED RENAL TUBULAR SECRETION OF DIGOXIN - THE TOXICOLOGICAL SIGNIFICANCE OF THE URINE-BLOOD BARRIER MODEL [J].
ITO, S ;
WOODLAND, C ;
HARPER, PA ;
KOREN, G .
LIFE SCIENCES, 1993, 53 (02) :PL25-PL31
[6]
Atrial fibrillation: A review of mechanism, etiology, and therapy [J].
Mackstaller, LL ;
Alpert, JS .
CLINICAL CARDIOLOGY, 1997, 20 (07) :640-650
[7]
RAVEL R, 1977, AM J MED TECHNOL, V43, P994
[8]
SHAPIRO B, 1975, Seminars in Nuclear Medicine, V5, P205, DOI 10.1016/S0001-2998(75)80010-9
[9]
STOLL RG, 1972, RES COMMUN CHEM PATH, V4, P503
[10]
STONE JA, 1989, CLIN CHEM, V35, P1326