Robotics in child neurosurgery

被引:10
作者
Giorgi, C
Sala, R
Riva, D
Cossu, A
Eisenberg, H
机构
[1] Ist Nazl Neurol, Div Neurosurg 1, I-20133 Milan, Italy
[2] Politecn Milan, Dept Mech, I-20133 Milan, Italy
[3] Ist Nazl Neurol, Div Dev Neurol, Milan, Italy
[4] UMMS Baltimore, Dept Neurosurg, Baltimore, MD USA
关键词
image-guided surgery; robotic microscope; robotic surgery; optical tracking;
D O I
10.1007/s003810000394
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We felt there was a need for a new device with "minimal invasive" tracking hardware, to be used in image-guided neurosurgery, and the system we designed to fill this need is now presented. It combines precision of movement, stability and self-positioning capabilities together with optically tracked registration and procedural control within the structure of a surgical microscope. The results are reduced setup time and minimal "distraction" from the procedure itself factors of special relevance in child neurosurgery. The system is composed of a six-axis industrial robot suitable for use in the operating room, carrying a surgical microscope. Three progressive scan-synchronized infrared cameras mounted around the lenses of the scope are used to register the patient's position and track surgical instruments with reference to the registered space. Orientation of the microscope during surgery is obtained with a six-axis joystick used as a microscope handle. The system has been clinically used in 14 cases, and it has proven itself to be reliable, providing the expected performance advantages. The implementation of a tracked ultrasound or endoscope intraoperative imaging source is also described.
引用
收藏
页码:832 / 834
页数:3
相关论文
共 9 条
  • [1] A FRAMELESS STEREOTAXIC OPERATING MICROSCOPE FOR NEUROSURGERY
    FRIETS, EM
    STROHBEHN, JW
    HATCH, JF
    ROBERTS, DW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (06) : 608 - 617
  • [2] GIORGI C, 1994, ACT NEUR S, V61, P43
  • [3] CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES
    GOLFINOS, JG
    FITZPATRICK, BC
    SMITH, LR
    SPETZLER, RF
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 197 - 205
  • [4] GUTHRIE BL, 1992, CLIN NEUR, V38, P112
  • [5] COMPUTER-ASSISTED STEREOTAXIC LASER RESECTION OF INTRAAXIAL BRAIN NEOPLASMS
    KELLY, PJ
    KALL, BA
    GOERSS, S
    EARNEST, F
    [J]. JOURNAL OF NEUROSURGERY, 1986, 64 (03) : 427 - 439
  • [6] ULTRASOUND-CONTROLLED NEURONAVIGATOR-GUIDED BRAIN SURGERY
    KOIVUKANGAS, J
    LOUHISALMI, Y
    ALAKUIJALA, J
    OIKARINEN, J
    [J]. JOURNAL OF NEUROSURGERY, 1993, 79 (01) : 36 - 42
  • [7] A ROBOT WITH IMPROVED ABSOLUTE POSITIONING ACCURACY FOR CT GUIDED STEREOTACTIC BRAIN SURGERY
    KWOH, YS
    HOU, J
    JONCKHEERE, EA
    HAYATI, S
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (02) : 153 - 160
  • [8] SONIC STEREOMETRY IN MICROSURGICAL PROCEDURES FOR DEEP-SEATED BRAIN-TUMORS AND VASCULAR MALFORMATIONS
    REINHARDT, HF
    HORSTMANN, GA
    GRATZL, O
    [J]. NEUROSURGERY, 1993, 32 (01) : 51 - 57
  • [9] 3-DIMENSIONAL DIGITIZER (NEURONAVIGATOR) - NEW EQUIPMENT FOR COMPUTED TOMOGRAPHY-GUIDED STEREOTAXIC SURGERY
    WATANABE, E
    WATANABE, T
    MANAKA, S
    MAYANAGI, Y
    TAKAKURA, K
    [J]. SURGICAL NEUROLOGY, 1987, 27 (06): : 543 - 547