Ventilation rates in mechanically-ventilated commercial poultry buildings in Southern Europe: Measurement system development and uncertainty analysis

被引:48
作者
Calvet, S. [1 ]
Cambra-Lopez, M. [1 ]
Blanes-Vidal, V. [2 ]
Estelles, F. [1 ]
Torres, A. G. [1 ]
机构
[1] Univ Politecn Valencia, Inst Anim Sci & Technol, Valencia 46022, Spain
[2] Univ So Denmark, Fac Engn, DK-5230 Odense, Denmark
关键词
LIVESTOCK BUILDINGS; ANIMAL FACILITIES; EMISSION RATES; AMMONIA; FLOW;
D O I
10.1016/j.biosystemseng.2010.05.006
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Measuring ventilation rate in intensive livestock buildings is important to improve the indoor environment and to determine the emission of gas pollutants from the building. However, measuring ventilation rates in commercial animal houses is difficult in practice. In this study a system to measure ventilation in a mechanically-ventilated commercial broiler farm with constant flow fans is presented. The system consisted of a low voltage DC circuit, connected to the signal circuit of the fan motor relays. Ventilation rate was determined hourly in one summer and one winter cycle (46 and 36 days, respectively), and the uncertainty of the measurements carried out by this system was evaluated. The system yielded accurate information regarding the time of operation of each fan and hourly ventilation rate, provided that the ventilation rate of each fan was known. Uncertainties in airflow measurement were evaluated using numerical Monte Carlo methods, being on average less than 10% of the measured value. The influence of the sampling frequency of fan status and the measurement of a partial number of fans in the building on the final uncertainty was also quantified. The ventilation rates and uncertainties determined using the developed system are valuable to determine total emissions and temporal emission patterns. (c) 2010 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:423 / 432
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[2]  
ASAE, 2003, EP2705 ASAE
[3]  
ASHRAE, 2001, ASHRAE FUND HDB
[4]   Ventilation flow in pig houses measured and calculated by carbon dioxide, moisture and heat balance equations [J].
Blanes, V ;
Pedersen, S .
BIOSYSTEMS ENGINEERING, 2005, 92 (04) :483-493
[5]  
BORIACK CK, 2004, 2004 ASAE CSAE INT M
[6]   On-Farm Ventilation Fan Performance Evaluations and Implications [J].
Casey, K. D. ;
Gates, R. S. ;
Wheeler, E. F. ;
Xin, H. ;
Liang, Y. ;
Pescatore, A. J. ;
Ford, M. J. .
JOURNAL OF APPLIED POULTRY RESEARCH, 2008, 17 (02) :283-295
[7]  
CASEY KD, 2002, QUALITY ASSURED ME 4
[8]  
Cox M.G., 2006, Technical report DEM-ES-011
[9]   Assessment of techniques for measuring the ventilation rate, using an experimental building section [J].
Demmers, TGM ;
Burgess, LR ;
Phillips, VR ;
Clark, JA ;
Wathes, CM .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 2000, 76 (01) :71-81
[10]   Ammonia emissions from two mechanically ventilated UK livestock buildings [J].
Demmers, TGM ;
Burgess, LR ;
Short, JL ;
Philips, VR ;
Clark, JA ;
Wathes, CM .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (02) :217-227