Direct determination of benzamides in serum by column-switching high-performance liquid chromatography

被引:27
作者
Chiba, R [1 ]
Ogasawara, A
Kubo, T
Yamazaki, H
Umino, M
Ishizuka, Y
机构
[1] Showa Pharmaceut Univ, Machida, Tokyo 1948543, Japan
[2] Tosoh Co, Sci Instrument Div, Ayase, Kanagawa 2521123, Japan
[3] Teikyo Univ, Sch Med, Mizonokuchi Hosp, Kawasaki, Kanagawa 2130001, Japan
关键词
D O I
10.2116/analsci.19.785
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A column-switching high-performance liquid chromatographic method with fluorescence detection was developed for the simultaneous determination of four benzamide-type anti-psychotic drugs: sulpiride, tiapride, sultopride and metoclopramide in human serum. In this method, a TSKgel Super-ODS column was used as an analytical column, and a TSKgel G 2000SW was prepared as a pretreatment column. Under the optimized analytical conditions, four benzamide-type anti-psychotic drugs were eluted within 18 min. The detection limits (SIN = 3) for sulpiride, tiapride, sultopride and metoclopramide are 1 ng/ml, 4 ng/ml, 2 ng/ml and 0.5 ng/ml, respectively. Finally, the method was applied to the determination of sulpiride in human serum samples obtained after a single oral dose of sulpiride.
引用
收藏
页码:785 / 789
页数:5
相关论文
共 23 条
[1]   QUANTITATIVE-ANALYSIS OF SULPIRIDE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
ALFREDSSON, G ;
SEDVALL, G ;
WIESEL, FA .
JOURNAL OF CHROMATOGRAPHY, 1979, 164 (02) :187-193
[2]  
BANA S, CLR840044
[3]   QUANTITATIVE-ANALYSIS OF SULPIRIDE AND SULTOPRIDE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR PHARMACOKINETIC STUDIES [J].
BRESSOLLE, F ;
BRES, J .
JOURNAL OF CHROMATOGRAPHY, 1985, 341 (02) :391-399
[4]   Effects of pH and solvent on the fluorescence properties of biomedically important benzamides. Application to determination in drugs and in human urine [J].
Buna, M ;
Aaron, JJ ;
Prognon, P ;
Mahuzier, G .
ANALYST, 1996, 121 (11) :1551-1556
[5]  
FRGERIO A, 1977, J CHROMATOGR, V361, P130
[6]  
FUJII K, 1993, IYAKUHIN KAGAKU SAYO, P36
[7]   INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY [J].
HAGESTAM, IH ;
PINKERTON, TC .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1757-1763
[8]   SYNTHESIS OF POLYMER-COATED MIXED-FUNCTIONAL PACKING MATERIALS FOR DIRECT ANALYSIS OF DRUG-CONTAINING SERUM AND PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KANDA, T ;
KUTSUNA, H ;
OHTSU, Y ;
YAMAGUCHI, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) :51-57
[9]  
KANDA T, 1998, CHROMATOGRAPHY, V19, P332
[10]  
KLEIMOLA T, 1976, ANN CLIN RES, V8, P104