In vitro flow analysis of a patient-specific intraatrial total cavopulmonary connection

被引:56
作者
de Zélicourt, DA
Pekkan, K
Wills, L
Kanter, K
Forbess, J
Sharma, S
Fogel, M
Yoganathan, AP
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Dept Surg, Atlanta, GA 30332 USA
[3] Emory Univ, Dept Pediat Cardiol, Atlanta, GA 30332 USA
[4] Childrens Hosp Philadelphia, Div Cardiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/j.athoracsur.2004.12.052
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Understanding the hemodynamics of the total cavopulmonary connection may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. Although most experimental and numerical investigations have mainly focused on somewhat simplified geometries, investigation of the flow field of true anatomic configurations is necessary for a true understanding. Methods. An intraatrial connection was reconstructed from patient magnetic resonance images and manufactured using transparent stereolithography. Power loss, flow visualization, and digital particle image velocimetry as well as computational fluid dynamics simulations were performed to characterize the anatomic flow structure. Given the complexity of the anatomic flow, two simplified versions of the geometry were manufactured and run through power loss and flow visualization studies. Results. Experimental measurements revealed complex, unsteady, and highly three-dimensional flow structures within the anatomic model, leading to high pressure drops and power losses. The small vessel diameters were the primary cause of these losses. Numerical simulations demonstrated that most of the dissipation occurred in the pulmonary arteries. Finally, asymmetric pulmonary diameters together with the bulgy intraatrial connection favored the rise of flow unsteadiness and unbalanced lung perfusion. Conclusions. The technique developed in this study enabled a deeper understanding of the hemodynamics behind an intraatrial connection. Future endeavors would be to study variation among differing surgical techniques, comparing intraatrial and extracardiac approaches. (c) 2005 by The Society of Thoracic Surgeons.
引用
收藏
页码:2094 / 2102
页数:9
相关论文
共 15 条
[1]   Flow on the symmetry plane of a total cavo-pulmonary connection [J].
Bolzon, G ;
Pedrizzetti, G ;
Grigioni, M ;
Zovatto, L ;
Daniele, C ;
D'Avenio, G .
JOURNAL OF BIOMECHANICS, 2002, 35 (05) :595-608
[2]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[3]  
DEZELICOURT D, IN PRESS J BIOMECH E
[4]   Toward designing the optimal total cavopulmonary connection: An in vitro study [J].
Ensley, AE ;
Lynch, P ;
Chatzimavroudis, GP ;
Lucas, C ;
Sharma, S ;
Yoganathan, AP .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1384-1390
[5]   SURGICAL REPAIR OF TRICUSPID ATRESIA [J].
FONTAN, F ;
BAUDET, E .
THORAX, 1971, 26 (03) :240-+
[6]  
Gersony DR, 2003, PROGR PEDIAT CARDIOL, V17, P73
[7]   Computational fluid dynamic study of flow optimization in realistic models of the total cavopulmonary connections [J].
Hsia, TY ;
Migliavacca, F ;
Pittaccio, S ;
Radaelli, A ;
Dubini, G ;
Pennati, G ;
de Leval, M .
JOURNAL OF SURGICAL RESEARCH, 2004, 116 (02) :305-313
[8]   Comparison of in vitro velocity measurements in a scaled total cavopulmonary connection with computational predictions [J].
Khunatorn, Y ;
Shandas, R ;
DeGroff, C ;
Mahalingam, S .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (07) :810-822
[9]   The effects of different mesh generation methods on computational fluid dynamic analysis and power loss assessment in total cavopulmonary connection [J].
Liu, YT ;
Pekkan, K ;
Jones, SC ;
Yoganathan, AP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (05) :594-603
[10]   Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: The influence of the inferior caval anastomosis [J].
Migliavacca, F ;
Dubini, G ;
Bove, EL ;
de Leval, MR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (06) :805-813