Computational fluid dynamic study of flow optimization in realistic models of the total cavopulmonary connections

被引:54
作者
Hsia, TY
Migliavacca, F
Pittaccio, S
Radaelli, A
Dubini, G
Pennati, G
de Leval, M
机构
[1] Johns Hopkins Univ Hosp, Div Cardiac Surg, Dept Surg, Baltimore, MD 21287 USA
[2] Great Ormond St Hosp Sick Children, Cardiothorac Unit, London WC1N 3JH, England
[3] Politecn Milan, Bioengn & Struct Engn Dept, I-20133 Milan, Italy
[4] Univ London Imperial Coll Sci Technol & Med, Dept Aeronaut, London, England
关键词
Fontan procedure; hemodynamics; modeling; physiopathology;
D O I
10.1016/j.jss.2003.08.004
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives and background. In the Fontan circulation, pulmonary and systemic vascular resistances are in series. The influence of various inferior vena cava to pulmonary artery connections in this unique circulatory arrangement was evaluated using computation fluid dynamics methods. Methods. Realistic three-dimensional models of total cavopulmonary connections were created from angiographic measurements to include the hepatic vein, superior vena cava, and branches of the pulmonary arteries. Steady-state finite volume analyses were performed using identical in vivo boundary conditions. Computational solutions calculated the percent hydraulic power dissipation and left-to-right pulmonary arterial flow distribution. Results. Simulations of the lateral tunnel, intraatrial tube, extracardiac conduit with left and right pulmonary artery anastomosis demonstrated extracardiac conduit with left pulmonary artery anastomosis having the lowest energy loss. Varying the extracardiac conduit from 10 to 30 mm. resulted in the least energy dissipation at 20 mm. Serial dilation of the lateral tunnel pathway showed a small incremental worsening of energy loss. Conclusions. Maximizing energy conservation in a low-energy flow domain, such as the Fontan circulation, can be significant to its fluid dynamic performance. Although computational modeling cannot predict postoperative failure or functional outcome, this study confirms the importance of local geometry of the surgically created pathway in the total cavopulmonary connection. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:305 / 313
页数:9
相关论文
共 21 条
[2]   The Fontan circulation: What have we learned? What to expect? [J].
de Leval, MR .
PEDIATRIC CARDIOLOGY, 1998, 19 (04) :316-320
[3]   Effect of vessel size on the flow efficiency of the total cavopulmonary connection: In vitro studies [J].
DeGroff, CG ;
Carlton, JD ;
Weinberg, CE ;
Ellison, MC ;
Shandas, R ;
Valdes-Cruz, L .
PEDIATRIC CARDIOLOGY, 2002, 23 (02) :171-177
[4]   Use of computational fluid dynamics in the design of surgical procedures: Application to the study of competitive flows in cavopulmonary connections [J].
deLeval, MR ;
Dubini, G ;
Migliavacca, F ;
Jalali, H ;
Camporini, G ;
Redington, A ;
Pietrabissa, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03) :502-510
[5]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[6]  
DUBINI G, 1996, J BIOMECH, V63, P930
[7]   Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse [J].
Fogel, MA ;
Weinberg, PM ;
Rychik, J ;
Hubbard, A ;
Jacobs, M ;
Spray, TL ;
Haselgrove, J .
CIRCULATION, 1999, 99 (09) :1215-1221
[8]   Does caval aplanarity influence power losses across in vitro cavopulmonary connections? [J].
Gerdes, A ;
Hanke, T ;
Ahrens, V ;
Pfister, G ;
Sievers, HH .
PEDIATRIC CARDIOLOGY, 2002, 23 (04) :388-393
[9]  
Hsia TY, 2000, HEART, V83, P583
[10]   Subdiaphragmatic venous hemodynamics in the Fontan circulation [J].
Hsia, TY ;
Khambadkone, S ;
Deanfield, JE ;
Taylor, JFN ;
Migliavacca, F ;
de Leval, MR .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (03) :436-447