DMS-IMS2, GC-DMS, DMS-MS: DMS hybrid devices combining orthogonal principles of separation for challenging applications - art. no. 69540H

被引:8
作者
Anderson, Andrew G. [1 ]
Markoski, Kenneth A. [1 ]
Shi, Quan [1 ]
Coy, Stephen L. [1 ]
Krylov, Evgeny V. [1 ]
Nazarov, Erkinjon G. [1 ]
机构
[1] Sionex Corp, Bedford, MA 01730 USA
来源
CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING IX | 2008年 / 6954卷
关键词
DMS; IMS; MS; GC; gas analysis; ion mobility;
D O I
10.1117/12.782429
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Sionex Differential Mobility Spectrometer (DMS) sensors can be used as standalone detectors in many applications because of their outstanding sensitivity and selectivity. However, in applications like field screening for toxic chemicals and explosives, the number of possible interferents may be so high that additional separation becomes useful for identification and for quantitative measurement. For these cases, we have developed several different hybrid technologies. (1) DMS-IMS2 integrates bipolar differential mobility ion filtration with IMS drift time measurement in IMS drift tubes, one tube for each ion polarity. (2)The Sionex GC-DMS (microAnalyzer) combines a pre-concentrator, a rapid and selective GC column that operates at high temperature in an air recirculation loop, and DMS ion filtration and detection. (3) Sionex DMS-MS interfaces have been developed for several types of mass spectrometers, and dramatically improve mass spec performance by filtering out unwanted species to reduce chemical noise and improve measurement accuracy. The Sionex DM S-IMS2 first uses DMS to select positive and negative ions based on ion mobility variation with field (the alpha(E) function), then uses paired IMS sections to measure the low field mobility (K(0)). DMS separation depends on many properties including the distribution of internal charges, rigidity, and clustering. The IMS drift times depend on molecular size and conformation at low fields. A number of applications of this technology will be described, including CWA's, TIC/TIM, and explosives. The Sionex microAnalyzer GC-DMS system combines sophisticated preconcentration, thermal desorption, GC temperature ramping, and DMS separation and detection in a compact, portable and field-deployable package. The list of applications for this technology is growing rapidly, currently including CWAs, BTEX, H2S and mercaptans, and others. Sionex DMS-MS interfaces are being used to make quantitative measurements of biomarkers, including breath markers, biofluid markers, and cancer-linked agents. DMS-MS improves the performance / cost tradeoff for the mass spectrometer, greatly speeds analysis compared to LC-MS, and maintains measurement accuracy.
引用
收藏
页码:H9540 / H9540
页数:12
相关论文
共 27 条
[1]  
ANDERSON AG, 2007, P PITTCON CHIC IL
[2]  
Badman ER, 2000, J MASS SPECTROM, V35, P659, DOI 10.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO
[3]  
2-V
[4]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[5]   Qualitative analysis of trace constituents by ion mobility increment spectrometer [J].
Buryakov, IA .
TALANTA, 2003, 61 (03) :369-375
[6]  
BURYAKOV IA, 1991, PISMA ZH TEKH FIZ+, V17, P60
[7]  
BURYAKOV UA, 1989, 1485808G01N2762 SU
[8]   Combining desorption electrospray ionization mass spectrometry and nuclear magnetic resonance for differential metabolomics without sample preparation [J].
Chen, Huanwen ;
Pan, Zhengzheng ;
Talaty, Nari ;
Raftery, Daniel ;
Cooks, R. Graham .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (10) :1577-1584
[9]   Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas [J].
Eiceman, GA ;
Krylov, EV ;
Nazarov, EG ;
Miller, RA .
ANALYTICAL CHEMISTRY, 2004, 76 (17) :4937-4944
[10]   Differential mobility spectrometry of chlorocarbons with a micro-fabricated drift tube [J].
Eiceman, GA ;
Krylov, EV ;
Tadjikov, B ;
Ewing, RG ;
Nazarov, EG ;
Miller, RA .
ANALYST, 2004, 129 (04) :297-304