Analysis of heat and mass transfer phenomena in hollow fiber membranes used for evaporative cooling

被引:74
作者
Johnson, DW [1 ]
Yavuzturk, C [1 ]
Pruis, J [1 ]
机构
[1] Univ Wyoming, Dept Civil & Architectural Engn, Laramie, WY 82071 USA
关键词
air humidification; fiber membranes; microporous and porous membranes; gas and vapor permeation; contactor design;
D O I
10.1016/j.memsci.2003.08.023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper describes the potential use of hollow fiber membranes in evaporative cooling applications for space air-conditioning. Duct-mountable hollow fiber membrane bundles and arrays are utilized as contactors for the delivery of liquid water to an air stream in a heating, ventilating air-conditioning duct. A series of experimental and analytical parametric studies are presented to assess the heat and mass transfer phenomena in evaporative cooling with hollow fiber membranes. The focus of the studies was to compare experimentally determined heat and mass transfer coefficients to estimates obtained from literature, to determine the influence of membrane and operating parameters on achievable mass and heat flux and to assess the efficacy of using hollow fiber membranes for evaporative cooling. The results point to a proof for the concept and further indicate that reasonable numbers of fibers and membrane surface area can provide cooling effectiveness comparable to conventional evaporative cooling equipment. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 171
页数:13
相关论文
共 19 条
[1]  
[Anonymous], 1988, HEAT TRANSFER TUBE B
[2]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[3]   Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors [J].
Bergero, S ;
Chiari, A .
APPLIED THERMAL ENGINEERING, 2001, 21 (11) :1119-1135
[4]  
Chiari A., 2001, INT J AMBIENT ENER, V21, P187
[5]   BUBBLE-FREE AERATION USING MEMBRANES - MASS-TRANSFER ANALYSIS [J].
COTE, P ;
BERSILLON, JL ;
HUYARD, A .
JOURNAL OF MEMBRANE SCIENCE, 1989, 47 (1-2) :91-106
[6]   A novel air conditioning system - Membrane air drying and evaporative cooling [J].
El-Dessouky, HT ;
Ettouney, HM ;
Bouhamra, W .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A7) :999-1009
[7]   Air gap membrane distillation of aqueous alcohol solutions [J].
García-Payo, MC ;
Izquierdo-Gil, MA ;
Fernández-Pineda, C .
JOURNAL OF MEMBRANE SCIENCE, 2000, 169 (01) :61-80
[8]   On the application of a membrane air-liquid contactor for air dehumidification [J].
Isetti, C ;
Nannei, E ;
Magrini, A .
ENERGY AND BUILDINGS, 1997, 25 (03) :185-193
[9]   Iron fouling in membrane gas transfer applications [J].
Kinnan, CM ;
Johnson, DW .
JOURNAL OF MEMBRANE SCIENCE, 2002, 205 (1-2) :45-71
[10]   A study of mass transfer in the membrane air-stripping process using microporous polyproplylene hollow fibers [J].
Mahmud, H ;
Kumar, A ;
Narbaitz, RM ;
Matsuura, T .
JOURNAL OF MEMBRANE SCIENCE, 2000, 179 (1-2) :29-41