Determination of trace metals in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry using metal alkoxide glass immobilized 8-quinolinol

被引:46
作者
Hirata, S
Kajiya, T
Takano, N
Aihara, M
Honda, K
Shikino, O
Nakayama, E
机构
[1] Natl Inst Adv Ind Sci & Technol, Hiroshima 7370197, Japan
[2] Kinki Univ, Higashihiroshima 7392116, Japan
[3] Perkin Elmer Japan Co Ltd, Suita, Osaka 5640051, Japan
[4] Univ Shiga Prefecture, Shiga 5220057, Japan
关键词
inductively coupled plasma mass spectrometry; MAF-8HQ; trace elements; seawater; on-line column preconcentration;
D O I
10.1016/S0003-2670(03)00949-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metal alkoxide glass immobilized 8-quinolinole (MAF-8HQ) was synthesized from the solutions for the resin for analysis of ultra trace level iron determination in seawater by Nakayama and Obata. Since the blank values of trace metals in the resin are very low, the resin was applied for the determination of trace metals in seawater. A home made column of MAF-8HQ was used to separate and concentrate trace metals (V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb and U) from seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) was used for the determination of trace metals in seawater. Sample solutions (adjusted to pH 5.5) were passed through the column. After washing the column with water, the adsorbed metals were subsequently eluted into the plasma with 0.7 M nitric acid. Detection limits (DLs) of the trace metals in the artificial seawater were 0.008 ng ml(-1) for V, 0.004 ng ml(-1) for Mn, 0.004 ng ml(-1) for Co, 0.014 ng ml(-1) for Ni, 0.014 ng ml(-1) for Cu, 0.050 ng ml(-1) for Zn, 0.002 ng ml(-1) for Mo, 0.003 ng ml(-1) for Cd, 0.017 ng ml(-1) for Pb and 0.001 ng ml(-1) for U, respectively, as the concentrations of analyte metals corresponding to three times (3sigma) the standard deviation of blank signal intensities by 10 replicate measurements. By using 120 s of sample loading times, 40-66-fold enrichment factors were obtained for V, Co, Cu, Zn, Cd, Pb and U. One sample can be processed in 7 ml and 7 min. The proposed method was verified by the analysis of trace metals in the two certified reference materials (CRMs) of seawater CASS-4 and NASS-5. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 30 条
[1]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[2]   Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor [J].
Benkhedda, K ;
Infante, HG ;
Ivanova, E ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :995-1001
[3]   Simplified synthesis of an 8-hydroxyquinoline chelating resin and a study of trace metal profiles from Jellyfish Lake, Palau [J].
Dierssen, H ;
Balzer, W ;
Landing, WM .
MARINE CHEMISTRY, 2001, 73 (3-4) :173-192
[4]   PRECONCENTRATION AND PURIFICATION OF RARE-EARTH ELEMENTS IN NATURAL-WATERS USING SILICA-IMMOBILIZED 8-HYDROXYQUINOLINE AND A SUPPORTED ORGANOPHOSPHORUS EXTRACTANT [J].
ESSER, BK ;
VOLPE, A ;
KENNEALLY, JM ;
SMITH, DK .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1736-1742
[5]  
FANG ZL, 1993, FLOW INJECTION SEPAR, P103
[6]   On-line method for inductively coupled plasma mass spectrometric determination of rare earth elements in highly saline brines [J].
Halicz, L ;
Gavrieli, I ;
Dorfman, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :811-814
[7]   SENSITIVITY ENHANCEMENTS FOR FLOW-INJECTION ANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HARTENSTEIN, SD ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :21-25
[8]   MINIMIZATION OF INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING ONLINE PRECONCENTRATION [J].
HEITHMAR, EM ;
HINNERS, TA ;
ROWAN, JT ;
RIVIELLO, JM .
ANALYTICAL CHEMISTRY, 1990, 62 (08) :857-864
[9]   Determination of rare earth elements in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Kajiya, T ;
Aihara, M ;
Honda, K ;
Shikino, O .
TALANTA, 2002, 58 (06) :1185-1194
[10]   DETERMINATION OF CHROMIUM(III), TITANIUM, VANADIUM, IRON(III), AND ALUMINUM BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HIRATA, S ;
UMEZAKI, Y ;
IKEDA, M .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2602-2606