Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples

被引:32
作者
Vintiloiu, A
Mullett, WM
Papp, R
Lubda, D
Kwong, E
机构
[1] Merck Frosst Ctr Therapeut Res, Kirkland, PQ H9H 3L1, Canada
[2] Merck KGaA, Dept Life Sci & Analyt, D-64293 Darmstadt, Germany
关键词
restricted access material; turbulent flow; on-line extraction; direct injection;
D O I
10.1016/j.chroma.2005.05.081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C-18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R-2 > 0.99) and reproducibility (%RSD <= 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:150 / 157
页数:8
相关论文
共 26 条
[1]   Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation [J].
Asperger, A ;
Efer, J ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :109-119
[2]   Optimisation and routine use of generic ultra-high flow-rate liquid chromatography with mass spectrometric detection for the direct on-line analysis of pharmaceuticals in plasma [J].
Ayrton, J ;
Dear, GJ ;
Leavens, WJ ;
Mallett, DN ;
Plumb, RS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :199-207
[3]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[4]  
2-Z
[5]  
Chan CC, 1999, J PHARMACOL EXP THER, V290, P551
[6]  
Chassaing C, 2001, CHROMATOGRAPHIA, V53, P122
[7]   High-performance liquid chromatographic-tandem mass spectrometric evaluation and determination of stable isotope labeled analogs of rofecoxib in human plasma samples from oral bioavailability studies [J].
Chavez-Eng, CM ;
Constanzer, ML ;
Matuszewski, BK .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01) :117-129
[8]  
EDGE T, 2002, CHROMATOGR SEP TECHN, V23, P10
[9]   Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry [J].
Grant, RP ;
Cameron, C ;
Mackenzie-McMurter, S .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1785-1792
[10]   Generic method for on-line extraction of drug substances in the presence of biological matrices using turbulent flow chromatography [J].
Herman, JL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (05) :421-426