Quality of motion considerations in numerical analysis of motion restoring implants of the spine

被引:35
作者
Bowden, Anton E. [1 ]
Guerin, Heather L. [1 ]
Villarraga, Marta L. [1 ]
Patwardhan, Avinash G. [2 ]
Ochoa, Jorge A. [3 ]
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Loyola Univ, Med Ctr, Maywood, IL 60153 USA
[3] Archus Orthoped, Redmond, WA USA
关键词
quality of motion; spine; finite element analysis; kinematic signature;
D O I
10.1016/j.clinbiomech.2007.12.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Background. Motion restoring implants function in a dynamic environment that encompasses the full range of spinal kinematics. Accurate assessment of the in situ performance of these devices using numerical techniques requires model verification and validation against the well-established nonlinear quality of motion of the spine, as opposed to the previous norm of matching kinematic endpoint metrics such as range of motion and intervertebral disc pressure measurements at a single kinematic reference point. Methods. Experimental data was obtained during cadaveric testing of nine three-functional spinal unit (L3-S1 ) lumbar spine segments. Each specimen was tested from 8 Nm of applied flexion moment to 6 Nm of applied extension moment with an applied 400 N compressive follower preload. A nonlinear kinematic curve representing the spinal quality of motion (applied moment versus angular rotation) for the index finite element model was constructed and compared to the kinematic responses of the experimental specimens. The effect of spinal soft tissue structure mechanical behaviors on the fidelity of the model's quality of motion to experimental data was assessed by iteratively modifying the material representations of annulus fibrosus, nucleus pulposus, and ligaments. Findings. The present work demonstrated that for this model, the annulus fibrosus played a small role in the nonlinear quality of motion of the model, whereas changes in ligament representations had a large effect, as validated against the full kinematic range of motion. An anisotropic continuum representation of the annulus fibrosus was used, along with nonlinear fabric representations of the ligaments and a hyperelastic representation of the nucleus pulposus. Interpretation. Our results suggest that improvements in current methodologies broadly used in numerical simulations of the lumbar spine are needed to fully describe the highly nonlinear motion of the spine. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:536 / 544
页数:9
相关论文
共 39 条
[1]
Relevance of in vitro and in vivo models for intervertebral disc degeneration [J].
An, HS ;
Masuda, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :88-94
[2]
Role of intra-abdominal pressure in the unloading and stabilization of the human spine during static lifting tasks [J].
Arjmand, N. ;
Shirazi-Adl, A. .
EUROPEAN SPINE JOURNAL, 2006, 15 (08) :1265-1275
[3]
Bathe K, 2007, Finite element procedures
[4]
Residual sagittal motion after lumbar fusion - A finite element analysis with implications on radiographic flexion-extension criteria [J].
Bono, Christopher M. ;
Khandha, Ashutosh ;
Vadapalli, S. ;
Holekamp, Scott ;
Goel, Vijay K. ;
Garfin, Steven R. .
SPINE, 2007, 32 (04) :417-422
[5]
A finite element model of the L5-S1 functional spinal unit: Development and comparison with biomechanical tests in vitro [J].
Charriere, E. ;
Sirey, F. ;
Zysset, P.K. .
Computer Methods in Biomechanics and Biomedical Engineering, 2003, 6 (04) :249-261
[6]
BIOMECHANICAL PROPERTIES OF SPINAL LIGAMENTS AND A HISTOLOGICAL STUDY OF THE SUPRASPINAL LIGAMENT IN TRACTION [J].
CHAZAL, J ;
TANGUY, A ;
BOURGES, M ;
GAUREL, G ;
ESCANDE, G ;
GUILLOT, M ;
VANNEUVILLE, G .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :167-176
[7]
CRIPTON PA, 2005, ROUNDTABLES SPINE SU, V1, P22
[8]
Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc [J].
Denozière, G ;
Ku, DN .
JOURNAL OF BIOMECHANICS, 2006, 39 (04) :766-775
[9]
New insight into the mechanics of the lumbar interspinous ligament [J].
Dickey, JP ;
Bednar, DA ;
Dumas, GA .
SPINE, 1996, 21 (23) :2720-2727
[10]
Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosus [J].
Eberlein, R ;
Holzapfel, GA ;
Fröhlich, M .
COMPUTATIONAL MECHANICS, 2004, 34 (02) :147-163