Realization of an infrared spectral radiant power response scale on a cryogenic bolometer

被引:10
作者
Migdall, A [1 ]
Eppeldauer, G [1 ]
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1088/0026-1394/35/4/16
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Institute of Standards and Technology (NIST) has developed an infrared (IR) radiant power response scale for the spectral range from 2 mu m to 20 mu m. The scale has been realized on a cryogenic bolometer. The response of this bolometer has been determined by multiple ties to a primary standard, the NIST High Accuracy Cryogenic Radiometer (HACR). These transfers were made using three intermediate detectors over three different spectral regions. In addition, an independent method was used to determine the relative response of the bolometer over the entire spectral range. An IR spectral response scale over the entire 2 mu m to 20 mu m range was determined from these measurements, with the interlocking nature of the multiple independent measurements providing improved overall confidence and reduced uncertainties. The overall scale combined standard uncertainty for the entire spectral range of 2 mu m to 20 mu m is of the order of 0.25%, with the typical combined standard uncertainty of an individual measurement made with the bolometer being similar to 0.8%.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 13 条
[1]  
Eppeldauer G, 1995, P SOC PHOTO-OPT INS, V2550, P36, DOI 10.1117/12.221416
[2]   CHARACTERIZATION OF A HIGH-SENSITIVITY COMPOSITE SILICON BOLOMETER [J].
EPPELDAUER, G ;
MIGDALL, AL ;
CROMER, CL .
METROLOGIA, 1993, 30 (04) :317-320
[3]  
EPPELDAUER G, 1994, ASME HTD, V277, P63
[4]   Realization of a scale of absolute spectral response using the national institute of standards and technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Cromer, CL .
APPLIED OPTICS, 1996, 35 (22) :4392-4403
[5]   Calibration of a pyroelectric detector at 10.6 mu m with the National Institute of Standards and Technology high-accuracy cryogenic radiometer [J].
Gentile, TR ;
Houston, JM ;
Eppeldauer, G ;
Migdall, AL ;
Cromer, CL .
APPLIED OPTICS, 1997, 36 (16) :3614-3621
[6]   The NIST high accuracy scale for absolute spectral response from 406 nm to 920 nm [J].
Larason, TC ;
Bruce, SS ;
Cromer, CL .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (02) :133-140
[7]  
LARASON TC, 1998, NATL I STAND TECHNOL
[8]  
MIGDALL A, 1994, P SOC PHOTO-OPT INS, V2227, P46, DOI 10.1117/12.178614
[9]  
MIGDALL AL, 1998, UNPUB NATL I STAND T
[10]   IMPROVED SPECTRAL RESPONSIVITY SCALES AT THE NPL, 400-NM TO 20-MU-M [J].
NETTLETON, DH ;
PRIOR, TR ;
WARD, TH .
METROLOGIA, 1993, 30 (04) :425-432