Isotope ratio determination of antimony from the transient signal of trimethylstibine by GC-MC-ICP-MS and GC-ICP-TOF-MS

被引:59
作者
Wehmeier, S
Ellam, R
Feldmann, J
机构
[1] Univ Aberdeen, Dept Chem, Aberdeen AB24 3UE, Scotland
[2] Scottish Univ Environm & Res Ctr, E Kilbride G75 0QF, Lanark, Scotland
关键词
D O I
10.1039/b302242k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotope ratio measurements of organometal(loid) species are of interest in order to determine isotope fractionation of the heavy metal(loid)s which can elucidate their pathways in the environment. We describe isotope ratio measurements of organoantimony using gas chromatography coupled to ICP-MS. We studied the influence of various parameters on the isotope ratio determination of the transient signal from trimethylstibine, using capillary gas chromatography coupled to both multicollector and time of flight ICP-MS with a simultaneous aspiration of aqueous samples creating wet plasma conditions. The influence of different mathematical models on the precision of the isotope ratio determination of transient signals was studied. The trapezium integration of full or half peak gave precisions of 0.08% and 0.02% using the MC-ICP-MS, whereas the ICP-TOF-MS gave values of around 0.2%. The multicollector ICP-MS used as a detector showed a chromatographic isotope fractionation of trimethylstibine. (CH3)(3)Sb-123 eluted earlier than (CH3)(3)Sb-121, with a shift of the 123/121 ratio of about 2%. Two different approaches were attempted to correct instrumental mass bias effects in order to descriminate natural isotope fractionation. First, we introduced Cd and Sb in aqueous solution simultaneously with the GC carrier and ICP Ar gas flow. Secondly, we used a standard-sample bracketing approach using a gas standard introduced via the GC. Real samples from a laboratory sewage sludge fermentor were measured and isotope fractionation of the biologically produced trimethylstibine was observed (delta Sb-123 +10 and +19parts per thousand). The gas samples were analysed for timethylstibine co-eluting with volatile organic compounds using GC-MS. Chloroform was found to co-elute, but had no significant influence on the isotope ratio of antimony in timethylstibine analysed by GC-ICP-MS. Hence, there would be a strong indication that isotope fractionation takes place when antimony is methylated by anaerobic bacteria.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 30 条
[1]   Nonbiological fractionation of iron isotopes [J].
Anbar, AD ;
Roe, JE ;
Barling, J ;
Nealson, KH .
SCIENCE, 2000, 288 (5463) :126-128
[2]   Antimony biomethylation by the wood rotting fungus Phaeolus schweinitzii [J].
Andrewes, P ;
Cullen, WR ;
Polishchuk, E ;
Reimer, KJ .
APPLIED ORGANOMETALLIC CHEMISTRY, 2001, 15 (06) :473-480
[3]  
[Anonymous], ORGANOMETALLIC COMPO
[4]  
Archer C, 2002, GEOCHIM COSMOCHIM AC, V66, pA26
[5]   Performance optimization of isotope ratio measurements in transient signals by FI-ICP-TOFMS [J].
Carrión, MC ;
Andrés, JR ;
Rubí, JAM ;
Emteborg, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :437-443
[6]   BIOLOGICAL METHYLATION [J].
CHALLENGER, F .
CHEMICAL REVIEWS, 1945, 36 (03) :315-361
[7]   THE ISOTOPIC ABUNDANCE OF ANTIMONY [J].
CHANG, TL ;
QIAN, QY ;
ZHAO, MT ;
WANG, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (01) :77-82
[8]  
Craig, 1986, ORGANOMETALLIC COMPO
[9]   Antimony speciation in freshwater plant extracts by using hydride generation gas chromatography mass spectrometry [J].
Dodd, M ;
Pergantis, SA ;
Cullen, WR ;
Li, H ;
Eigendorf, GK ;
Reimer, KJ .
ANALYST, 1996, 121 (02) :223-228
[10]   Isotope ratio and isotope dilution measurements using axial inductively coupled plasma time of flight mass spectrometry [J].
Emteborg, H ;
Tian, XD ;
Ostermann, M ;
Berglund, M ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) :239-246