Isotope ratio and isotope dilution measurements using axial inductively coupled plasma time of flight mass spectrometry

被引:45
作者
Emteborg, H
Tian, XD
Ostermann, M
Berglund, M
Adams, FC
机构
[1] Univ Instelling Antwerp, Dept Chem, MiTAC, Micro & Trace Anal Ctr, B-2610 Antwerp, Belgium
[2] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
D O I
10.1039/a909575f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Performance of axial ICP-TOF-MS in terms of precision and mass bias for isotope ratio measurements and accuracy of isotope dilution was assessed by measurements of isotopic reference materials for Li, Mg, Rb, Pt and Pb. Because of simultaneous ion extraction from the plasma, remaining flicker noise is minimized resulting in improved precision for isotope ratios compared to sequential mass spectrometers. Experimental relative standard deviations of < 0.05% for isotope ratios were obtained at high signal levels measured in the analog detection mode. Effects on isotope ratios derived from changes of instrumental parameters, such as detector voltage and transverse rejection ion pulse settings, were evaluated. Isotope ratios for different concentrations changed when operating at too low detector voltages. An appropriate detector voltage setting is important but optimum voltages differ depending on the age and previous history of the detector. Results obtained for ID measurements of magnesium and rubidium amount content compared well with results from quadrupole ICP-MS and thermal ionization mass spectrometry. Mass bias per mass unit is high in the low mass range (13% for Li-6/Li-7) but around 0.2% in the high mass range. The long-term stability of ratios, measured discontinuously over several hours, is moderate; therefore measurements of an isotopic reference material at regular intervals is necessary to correct for small variations in mass bias over time.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 23 条
[1]   ADVANCES IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - HUMAN-NUTRITION AND TOXICOLOGY [J].
BARNES, RM .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :115-130
[2]  
BENETEAU SB, 1992, ATOM SPECTROSC, V13, P118
[3]   Quality assurance of arsenic, lead, tin and zinc in copper alloys using axial inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) [J].
Emteborg, H ;
Tian, XD ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1567-1572
[4]   DETERMINATION OF SOURCES OF LEAD IN TAP WATER BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) [J].
HALL, ES ;
MURPHY, E .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1993, 175 (02) :129-138
[5]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[6]  
Ingle J.D., 1988, SPECTROCHEMICAL ANAL, P135
[7]  
International Organization for Standardization, 1993, GUID EXPR UNC MEAS
[8]  
JANGHORBANI M, 1989, MIKROCHIM ACTA, V3, P315
[9]   The Comite Consultatif pour la Quantite de Matiere: A brief review of its origin and present activities [J].
Kaarls, R ;
Quinn, TJ .
METROLOGIA, 1997, 34 (01) :1-5
[10]   Uptake of ingested uranium after low "acute intake" [J].
Karpas, Z ;
Lorber, A ;
Elish, E ;
Kol, R ;
Roiz, Y ;
Marko, R ;
Katorza, E ;
Halicz, L ;
Riondato, J ;
Vanhaecke, F ;
Moens, L .
HEALTH PHYSICS, 1998, 74 (03) :337-345