Flow injection spectrophotometric determination of tenoxicam

被引:17
作者
Al-Tamrah, SA [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Riyadh 11451, Saudi Arabia
关键词
spectrophotometric; tenoxicam; hexacyanoferrate;
D O I
10.1016/S0003-2670(98)00410-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new spectrophotometric flow injection method has been established for the determination of tenoxicam [4-hydroxy-2,methyl-N-2-pyridyl-2H-thieno(2,3-e)-1,2-thiazine-3-carboxamide-1,1-dioxide]. The method is based on the reaction of tenoxicam with iron(III) nitrate. The produced iron(II) reacts with potassium hexacyanoferrate(III) forming Prussian blue measurable at 724 nm. Maximum colour formation was obtained through heating. The blue complex that gradually adhered to the flow hues and the flow cell walls was removed by employing an alkaline oxalate solution. Linearity was in the range 0.5-100 mu g ml(-1) tenoxicam with a limit of detection (signal:noise=3) of 0.4 mu g ml(-1). The method was successfully applied to the determination of tenoxicam in pharmaceutical preparations. The correlation coefficient was 0.99943 (n=8) with a relative standard deviation of 1.04%, for five determinations of 5 mu g ml(-1) drug. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 11 条
[1]  
ALAMOUD AI, 1995, THESIS KING SAUD U R
[2]  
Atkobar Z, 1996, ANAL LETT, V29, P2383
[3]   DETERMINATION OF TENOXICAM, AND THE ISOLATION, IDENTIFICATION AND DETERMINATION OF RO 17-6661, ITS MAJOR METABOLITE, IN HUMAN-URINE [J].
DELL, D ;
JOLY, R ;
MEISTER, W ;
ARNOLD, W ;
PARTOS, C ;
GULDIMANN, B .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :483-492
[4]   RAPID METHOD FOR THE DETERMINATION OF EITHER PIROXICAM OR TENOXICAM IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DIXON, JS ;
LOWE, JR ;
GALLOWAY, DB .
JOURNAL OF CHROMATOGRAPHY, 1984, 310 (02) :455-459
[5]   SQUARE-WAVE AND SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRIC COMPARISON OF THE ANTIINFLAMMATORY DRUGS PIROXICAM AND TENOXICAM [J].
ELMAALI, NA ;
VIRE, JC ;
PATRIARCHE, GJ ;
GHANDOUR, MA ;
CHRISTIAN, GD .
ANALYTICAL SCIENCES, 1990, 6 (02) :245-250
[6]  
GONZALES JF, 1987, DRUGS, V34, P298
[7]   DETERMINATION OF TENOXICAM IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HEIZMANN, P ;
KORNER, J ;
ZINAPOLD, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 374 (01) :95-102
[8]  
*MERCK, 1989, MERCK IND, P1441
[9]   DETERMINATION OF TENOXICAM IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
MUNERAJARAMILLO, MI ;
BOTEROGARCES, S .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02) :349-352
[10]   OXICAMS - METABOLIC DISPOSITION IN MAN AND ANIMALS [J].
WOOLF, TF ;
RADULOVIC, LL .
DRUG METABOLISM REVIEWS, 1989, 21 (02) :255-276