Validation of a model-based segmentation approach to propagating normal anatomic regions of interest through the 10 phases of respiration

被引:10
作者
Ezhil, Muthuveni [1 ,2 ]
Starkschall, George [1 ]
Mohan, Radhe [1 ]
Cox, James [2 ]
Komaki, Ritsuko [2 ]
机构
[1] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 71卷 / 03期
关键词
model-based segmentation; 4D CT images; respiratory phases; propagation of contours;
D O I
10.1016/j.ijrobp.2008.02.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To validate a model-based segmentation (MBS) algorithm in a commercial radiation treatment planning system for use in propagating the contours of normal anatomic regions of interest (ROIs) through the respiratory phases that constitute a four-dimensional (4D) computed tomography (CT) image data set. Methods and Materials: The 41) CT data sets for 12 patients treated for non-small-cell lung cancer were acquired. Five ROIs were selected for delineation: right and left lungs, spinal cord, heart, and esophagus. These ROIs; were manually delineated on the CT data set corresponding to the end-inspiration respiratory phase (0%). An MBS algorithm implemented on the treatment planning system propagated the ROIs sequentially through the respiratory phases that constituted the 4D CT data sets, concluding with the 0% phase data set, which was propagated from the 90 % phase data set. The propagated ROIs on the 0 % phase were compared with the original ROIs on that phase by using visual assessment and a quantitative measure of coincidence. Results: Acceptable propagation accuracy within 1 mm of uncertainty was achieved for lungs and spinal cord. Propagation of the heart produced slightly larger contours that were similar to interphysician variations in contouring the heart. The esophagus was poorly propagated because of lack of tissue contrast and definitive shape. Conclusions: The MBS propagation is a promising tool for efficiently propagating contours through the different phases of respiration. However, propagating the esophagus through this technique may be difficult because of the lack of definitive shape and clearer boundaries from surrounding tissue. (C) 2008 Elsevier Inc.
引用
收藏
页码:900 / 906
页数:7
相关论文
共 9 条
[1]  
Collier Dawn C, 2003, J Appl Clin Med Phys, V4, P17, DOI 10.1120/1.1521271
[2]   Assessment of a model-based deformable image registration approach for radiation therapy planning [J].
Kaus, Michael R. ;
Brock, Kristy K. ;
Pekar, Vladimir ;
Dawson, Laura A. ;
Nichol, Alan M. ;
Jaffray, David A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02) :572-580
[3]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[4]   AUTOMATIC OUTLINING OF REGIONS ON CT SCANS [J].
KELLER, JM ;
EDWARDS, FM ;
RUNDLE, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (02) :240-245
[5]   Impact of respiratory motion on dose distributions and DVHs of thoracic structures - Evaluation using 4DCT [J].
Liu, H ;
Wei, X ;
Jang, S ;
Jauregui, M ;
Dong, L ;
Batter, P ;
Luo, D ;
Pan, T ;
Hunjan, S ;
Starkschall, G ;
Rosen, I ;
Prado, K ;
Liao, Z ;
Chang, J ;
Komaki, R ;
Mohan, R .
MEDICAL PHYSICS, 2005, 32 (06) :1924-1924
[6]   The potential for dose escalation in lung cancer as a result of systematically reducing margins used to generate planning target volume [J].
Nelson, C ;
Starkschall, G ;
Chang, JY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :573-586
[7]   4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J].
Pan, T ;
Lee, TY ;
Rietzel, E ;
Chen, GTY .
MEDICAL PHYSICS, 2004, 31 (02) :333-340
[8]   Automated model-based organ delineation for radiotherapy planning in prostatic region [J].
Pekar, V ;
McNutt, TR ;
Kaus, MR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03) :973-980
[9]   Semiautomated four-dimensional computed tomography segmentation using deformable models [J].
Ragan, D ;
Starkschall, G ;
McNutt, T ;
Kaus, M ;
Guerrero, T ;
Stevens, CW .
MEDICAL PHYSICS, 2005, 32 (07) :2254-2261