Polyurethane foam as a sorbent for continuous flow analysis: Preconcentration and spectrophotometric determination of zinc in biological materials

被引:65
作者
de Jesus, DS
Casella, RJ
Ferreira, SLC
Costa, ACS
de Carvalho, MS
Santelli, RE [1 ]
机构
[1] Univ Fed Fluminense, Dept Geochem, BR-24020007 Niteroi, RJ, Brazil
[2] Fed Bahia Ctr Technol Educ, Salvador, BA, Brazil
[3] Fed Sch Tech Chem, Rio De Janeiro, Brazil
[4] Univ Fed Bahia, Inst Chem, Dept Analyt Chem, BR-40170290 Salvador, BA, Brazil
[5] CNEN, IEN, Nucl Engineer Inst, Rio De Janeiro, Brazil
[6] Univ Fed Fluminense, Dept Geochem, BR-24020007 Niteroi, RJ, Brazil
关键词
polyurethane foam; zinc preconcentration; continuous flow analysis; biological samples;
D O I
10.1016/S0003-2670(98)00111-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and accurate procedure was developed to preconcentrate and determine zinc in biological matrices. A polyurethane foam (PUF) minicolumn was used for the first time for on-line preconcentration. This system was applied to preconcentrate zinc from aqueous solutions which is sorbed as zinc-thiocyanate complex. Then, the complex was eluted by water and zinc was determined by spectrophotometry using 4-(2-pyridylazo)-resorcinol. The method was validated by the analysis of several biological certified reference materials. The detection limit was 0.9 ng ml(-1) and the RSD was 1.2% for 1 min preconcentration time. Generally, concentration of Fe(III), Al(III), Mo(VI), Ni(II), Mn(II), Cu(II), and Co(II) found in biological matrices did not interfere. Dynamic ranges of concentration from 20 to 100 ng ml(-1) (1 min preconcentration time) and from 5 to 20 ng ml(-1) (5 min preconcentration time) achieve a sample throughput of 20 and 8 samples per hour and a preconcentration factor of 8 and 32, respectively. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 35 条
[21]  
LIMA R, 1996, TALANTA, V43, P983
[22]   DETERMINATION OF NICKEL IN ROCKS BY USE OF A CONTINUOUS PRECIPITATION PRECONCENTRATION SYSTEM COUPLED ONLINE TO A FLAME ATOMIC-ABSORPTION SPECTROMETER [J].
MENDES, PCS ;
SANTELLI, RE ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :663-666
[23]  
Moody G. J., 1983, ANAL PROC, V20, P132
[24]   FLAME AAS DETERMINATION OF LEAD IN WATER WITH FLOW-INJECTION PRECONCENTRATION AND SPECIATION USING FUNCTIONALIZED CELLULOSE SORBENT [J].
NAGHMUSH, AM ;
PYRZYNSKA, K ;
TROJANOWICZ, M .
TALANTA, 1995, 42 (06) :851-860
[25]  
*NAT I ENV STUD, 1989, NIES CERT REF MAT
[26]   UNLOADED POLYETHER TYPE POLYURETHANE FOAMS AS SOLID EXTRACTANTS FOR TRACE-ELEMENTS [J].
PALAGYI, S ;
BRAUN, T .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 163 (01) :69-79
[27]  
Palagyi S., 1992, PRECONCENTRATION TEC
[28]   SORBENT EXTRACTION IN FLOW-INJECTION ANALYSIS AND ITS APPLICATION TO ENHANCEMENT OF ATOMIC SPECTROMETRY [J].
RUZICKA, J ;
ARNDAL, A .
ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) :243-255
[29]  
Ruzicka Jaromir., 1988, FLOW INJECTION ANAL, V2nd
[30]   PRECONCENTRATION AND ATOMIC-ABSORPTION DETERMINATION OF COPPER TRACES IN WATERS BY ONLINE ADSORPTION-ELUTION ON AN ACTIVATED CARBON MINICOLUMN [J].
SANTELLI, RE ;
GALLEGO, M ;
VALCARCEL, M .
TALANTA, 1994, 41 (05) :817-823