Iliac fixation length and resistance to in-vivo stent-graft displacement

被引:30
作者
Arko, FR [1 ]
Heikkinen, M [1 ]
Lee, ES [1 ]
Bass, A [1 ]
Alsac, JM [1 ]
Zarins, CK [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Vasc Surg, Stanford, CA 94305 USA
关键词
D O I
10.1016/j.jvs.2004.12.050
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Migration of endovascular stent grafts has been related to the security of proximal device fixation to the aortic neck. This study evaluated the importance of iliac fixation in preventing longitudinal in vivo device displacement of a modular, externally supported stent graft. Methods: Experimental ovine infrarenal aneurysms (n = 8) were treated with a fully supported, modular, bifurcated stent graft (AneuRx, Medtronic, Santa Rosa, Calif). Minimum iliac fixation length (1 cm) was used in four animals and iliac extender modules were used to achieve maximum iliac fixation in four animals. Suture anastomosis of bifurcated polyester grafts to the infrarenal aorta served as controls (n = 8). Aortic grafts were displaced in vivo by applying downward traction to a guidewire that was passed over the iliac flow divider and brought out both femoral arteries. The displacement force needed to initiate stem-graft migration was recorded and compared with the force needed to disrupt the sutured anastomosis. Results: There was no difference in animal weight (88.8 +/- 2.5 kg vs 87.5 +/- 2.9 kg), aortic neck diameter (12.7 +/- 0.9 mm vs 13.4 +/- 1.1 mm), aortic neck length (23.2 +/- 0.9 mm vs 21.8 +/- 2.4 mm), experimental aneurysm size (24.7 +/- 1.1 mm vs 24.2 +/- 2.0 mm), or iliac artery diameter (9.0 +/- 1.5 mm vs 9.3 +/- 0.5 mm) among the groups. Iliac fixation length was 31.0 +/- 0.3 mm in the maximum iliac fixation group and 11 +/- 0.25 mm in the minimum fixation group (P < .0001). Peak displacement force to initiate migration was 30.2 +/- 5.5 N (range, 25 to 38) in animals with maximum iliac fixation compared with 18.1 +/- 3.7 N (range, 13 to 21) in those with minimum fixation (P = .01). The force needed to disrupt the control surgical anastomosis was 40.6 +/- 7.5 N (range, 31 to 50) (P < .01). Conclusions: Maximizing iliac fixation length increases the longitudinal in vivo force needed to displace a fully supported stent graft by 67%. This suggests that increasing iliac fixation length may reduce the long-term risk of migration in patients undergoing endovascular aneurysm repair.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 30 条
  • [1] Anatomical risk factors for proximal perigraft endoleak and graft migration following endovascular repair of abdominal aortic aneurysms
    Albertini, JN
    Kalliafas, S
    Travis, S
    Yusuf, SW
    Macierewicz, JA
    Whitaker, SC
    Elmarasy, NM
    Hopkinson, BR
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 19 (03) : 308 - 312
  • [2] Aneurysm-related death: Primary endpoint analysis for comparison of open and endovascular repair
    Arko, FR
    Lee, WA
    Hill, BB
    Olcott, C
    Dalman, RL
    Harris, EJ
    Cipriano, P
    Fogarty, TJ
    Zarins, CK
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 36 (02) : 297 - 304
  • [3] Stent-graft design: the good, the bad and the ugly
    Chuter, TAM
    [J]. CARDIOVASCULAR SURGERY, 2002, 10 (01): : 7 - 13
  • [4] Endovascular stent grafting in the presence of aortic neck filling defects: Early clinical experience
    Gitlitz, DB
    Ramaswami, G
    Kaplan, D
    Hollier, LH
    Marin, ML
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) : 340 - 344
  • [5] Zenith AAA endovascular graft: Intermediateterm results of the US multicenter trial
    Greenberg, RK
    Chuter, TAM
    Sternbergh, C
    Fearnot, NE
    [J]. JOURNAL OF VASCULAR SURGERY, 2004, 39 (06) : 1209 - 1218
  • [6] Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial
    Greenhalgh, RM
    Brown, LC
    Kwong, GPS
    Powell, JT
    Thompson, SG
    [J]. LANCET, 2004, 364 (9437) : 843 - 848
  • [7] HEIKKINEN MA, 2005, 29 ANN M SO ASS VASC
  • [8] Mechanical failure of prosthetic human implants: A 10-year experience with aortic stent graft devices
    Jacobs, TS
    Won, J
    Gravereaux, EC
    Faries, PL
    Morrissey, N
    Teodorescu, VJ
    Hollier, LH
    Marin, ML
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 37 (01) : 16 - 26
  • [9] Kalliafas S, 2002, J ENDOVASC THER, V9, P743, DOI 10.1583/1545-1550(2002)009<0743:SGMAER>2.0.CO
  • [10] 2