Improving quantitative gas chromatography-electron ionization mass spectrometry results using a modified ion source: Demonstration for a pharmaceutical application

被引:3
作者
D'Autry, Ward [1 ]
Wolfs, Kris [1 ]
Hoogmartens, Jos [1 ]
Adams, Erwin [1 ]
Van Schepdael, Ann [1 ]
机构
[1] Katholieke Univ Leuven, Lab Pharmaceut Anal, Fac Pharmaceut Sci, B-3000 Louvain, Belgium
关键词
Electron ionization; Gold coating; Residual solvents; Static headspace-gas chromatography; Validation;
D O I
10.1016/j.chroma.2011.05.014
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Gas chromatography-mass spectrometry is a well established analytical technique. However, mass spectrometers with electron ionization sources may suffer from signal drifts, hereby negatively influencing quantitative performance. To demonstrate this phenomenon for a real application, a static headspace-gas chromatography method in combination with electron ionization-quadrupole mass spectrometry was optimized for the determination of residual dichloromethane in coronary stent coatings. Validating the method, the quantitative performance of an original stainless steel ion source was compared to that of a modified ion source. Ion source modification included the application of a gold coating on the repeller and exit plate. Several validation aspects such as limit of detection, limit of quantification, linearity and precision were evaluated using both ion sources. It was found that, as expected, the stainless steel ion source suffered from signal drift. As a consequence, non-linearity and high RSD values for repeated analyses were obtained. An additional experiment was performed to check whether an internal standard compound would lead to better results. It was found that the signal drift patterns of the analyte and internal standard were different, consequently leading to high RSD values for the response factor. With the modified ion source however, a more stable signal was observed resulting in acceptable linearity and precision. Moreover, it was also found that sensitivity improved compared to the stainless steel ion source. Finally, the optimized method with the modified ion source was applied to determine residual dichloromethane in the coating of coronary stents. The solvent was detected but found to be below the limit of quantification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4034 / 4038
页数:5
相关论文
共 16 条
[1]
[Anonymous], 1994, INT C HARM TECHN REQ
[2]
[Anonymous], 2010, EUR PHARM
[3]
[Anonymous], 2009, INT C HARM TECHN REQ
[4]
Bruner F., 1993, Gas chromatographic environmental analysis: principles, techniques, instrumentation
[5]
Characterization and Improvement of Signal Drift Associated with Electron Ionization Quadrupole Mass Spectrometry [J].
D'Autry, Ward ;
Wolfs, Kris ;
Yarramraju, Sitaramaraju ;
Van Schepdael, Ann ;
Hoogmartens, Jos ;
Adams, Erwin .
ANALYTICAL CHEMISTRY, 2010, 82 (15) :6480-6486
[6]
Pharmaceutical Aspects of Drug Eluting Stents [J].
Deconinck, E. ;
Sohier, I. ;
De Scheerder, I. ;
Van Den Mooter, G. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 97 (12) :5047-5060
[7]
HASKINS N, 2003, PHARM ANAL, P165
[8]
Hubschmann H. J., 2009, HDB GC MS FUNDAMENTA
[9]
Johnstone R., 1996, MASS SPECTROMETRY CH, V2nd
[10]
McMaster M.C., 2008, GC-MS: A practical user's guide