Direct determination of stability of protease inhibitors in plasma by HPLC with automated column-switching

被引:14
作者
Peng, SX [1 ]
Strojnowski, MJ [1 ]
Bornes, DM [1 ]
机构
[1] Procter & Gamble Co, Hlth Care Res Ctr, Mason, OH 45040 USA
关键词
column-switching; RAM column; MMP inhibitors; drug stability;
D O I
10.1016/S0731-7085(98)00127-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Automated column-switching HPLC methods were developed and utilized for the direct analyses of three hydroxamic acid based metalloprotease inhibitors in rat plasma. These column-switching methods involved the use of a restricted-access media (RAM) precolumn and a column-switching valve, allowing the complete automation of sample preparation and HPLC. The plasma samples were directly injected onto a precolumn packed with SPS/ODS stationary phase and then backflushed onto an ODS analytical column using a 6-port column-switching device. The drug stability in rat plasma was determined using both the automated and traditional HPLC methods. The results obtained from the automated column-switching methods were in good agreement with those from traditional methods that involve sequential protein precipitation, liquid extraction, solvent evaporation, and sample reconstitution. In addition to the elimination of labor-intensive and time-consuming sample preparation procedures, the column-switching methods allowed on-line analyte enrichment and accurate determination of drug stability in plasma with detection limits in the range of 10-20 ng ml(-1). This work represents, for the first time, a drug stability study in plasma by automated column-switching HPLC technique with the use of a RAM column. Our column-switching methods can be readily adapted to any existing HPLC system with minimal hardware modification. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 15 条
[1]  
Boos KS, 1997, LC GC-MAG SEP SCI, V15, P602
[2]   THE MEASUREMENT OF WARFARIN ENANTIOMERS IN SERUM USING COUPLED ACHIRAL CHIRAL, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) [J].
CHU, YQ ;
WAINER, IW .
PHARMACEUTICAL RESEARCH, 1988, 5 (10) :680-683
[3]   SEMIPERMEABLE-SURFACE REVERSED-PHASE MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DESILETS, CP ;
ROUNDS, MA ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :25-39
[4]   INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY [J].
HAGESTAM, IH ;
PINKERTON, TC .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1757-1763
[5]   MONITORING OF BENZODIAZEPINES (CLOBAZAM, DIAZEPAM AND THEIR MAIN ACTIVE METABOLITES) IN HUMAN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LACROIX, C ;
WOJCIECHOWSKI, F ;
DANGER, P .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 617 (02) :285-290
[6]   COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF SK-AND-F-106203 IN HUMAN PLASMA AFTER FLUORESCENCE DERIVATIZATION WITH 9-ANTHRYLDIAZOMETHANE [J].
MILLERSTEIN, C ;
HWANG, BYH ;
RHODES, GR ;
BOPPANA, VK .
JOURNAL OF CHROMATOGRAPHY, 1993, 631 (1-2) :233-240
[7]   Selective extraction of beta-blockers from biological fluids by column-switching high-performance liquid chromatography using an internal-surface phenylboronic acid precolumn [J].
Ohta, T ;
Niida, S ;
Nakamura, H .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 675 (01) :168-173
[8]  
Pinkerton T. C., 1986, BIOCHROMATOGRAPHY, V1, P96
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PACKING MATERIALS FOR THE ANALYSIS OF SMALL MOLECULES IN BIOLOGICAL MATRICES BY DIRECT INJECTION [J].
PINKERTON, TC .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :13-23
[10]   MULTIDIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON PINKERTON ISRP AND RP18 COLUMNS - DIRECT SERUM INJECTION TO QUANTIFY CREATININE [J].
PUHLMANN, A ;
DULFFER, T ;
KOBOLD, U .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 581 (01) :129-133