Synergistic substrates determination with biosensors

被引:16
作者
Kulys, J [1 ]
Tetianec, L [1 ]
机构
[1] Lithuania Acad Sci, Inst Biochem, LT-08662 Vilnius, Lithuania
关键词
biosensor; carbohydrate oxidase; glucose oxidase; cation radical; mediator; hexacyanoferrate(III); modeling;
D O I
10.1016/j.bios.2004.08.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
High sensitive biosensors for heterocyclic compounds determination were built using oxidases-catalyzed hexacyanoferrate(III) reduction in the presence of these compounds. As oxidases Aspergillus niger glucose oxidase and recombinant Microdochium nivale carbohydrate oxidase were used. The biosensors were build using graphite electrodes and entrapped solution of the oxidases. The sensitivity of the biosensors achieves 5.2-14.5 mu A mu M-1 cm(-2). The detection limit of some heterocyclic compounds was 0.2 mu M. The sensitivity of biosensors was 300-10,000 times larger in comparison to hexacyanoferrate(III). To background the scheme of biosensors action kinetics of synergistic substrates oxidation was investigated in homogenous solution. The measurements showed that the rate of the reduction of low reactive substrate (hexacyanoferrate(III)) increased due to synergistic action of high reactive substrates (oxidized heterocyclic compounds). The modeling revealed the limiting step of the process. The increase of hexacyanoferrate(III) reduction rate is determined by the rate of reduced enzymes interaction with oxidized heterocyclic compound. The oxidation of heterocyclic compounds (mediators) with hexacyanoferrate(III) does not limit the process. The analysis of macrokinetics of biosensors action showed that synergistic effect may be realized and high biosensors sensitivity may be achieved if diffusion module of the enzyme reaction with the oxidized mediator and of a cross reaction is larger than 0.5. The calculated relative sensitivity is about three times higher in comparison to experimentally determined that may be caused by the limited stability of oxidized heterocyclic compounds and/or some external diffusion limitation of substrates. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 28 条
[1]
Molecular recognition of artificial single-electron acceptor cosubstrates by glucose oxidase? [J].
Alzari, P ;
Anicet, N ;
Bourdillon, C ;
Moiroux, J ;
Saveant, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (28) :6788-6789
[2]
[Anonymous], 1994, CRC HDB CHEM PHYS
[3]
Modelling amperometric enzyme electrode with substrate cyclic conversion [J].
Baronas, R ;
Kulys, J ;
Ivanauskas, F .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) :915-922
[4]
BOURDILLON C, 1993, J AM CHEM SOC, V115, P2
[5]
FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]
INDUCTION OF REPAIRABLE DNA DAMAGE IN ESCHERICHIA-COLI AND INTERACTION WITH DNA INVITRO BY THE RADICAL CATION OF CHLORPROMAZINE [J].
DEMOL, NJ ;
POSTHUMA, RM ;
MOHN, GR .
CHEMICO-BIOLOGICAL INTERACTIONS, 1983, 47 (02) :223-237
[7]
The influence of structure in the reaction of electrochemically generated ferrocenium derivatives with reduced glucose oxidase [J].
Forrow, NJ ;
Sanghera, GS ;
Walters, SJ .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 2002, (16) :3187-3194
[8]
Hydrogen tunneling in biology [J].
Kohen, A ;
Klinman, JP .
CHEMISTRY & BIOLOGY, 1999, 6 (07) :R191-R198
[9]
LONG-TERM RESPONSE OF AN INTEGRATED CARBON-PASTE BASED GLUCOSE BIOSENSOR [J].
KULYS, J ;
HANSEN, HE .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :285-294
[10]
Kinetics and thermodynamics of peroxidase- and laccase-catalyzed oxidation of N-substituted phenothiazines and phenoxazines [J].
Kulys, J ;
Krikstopaitis, K ;
Ziemys, A .
JOURNAL OF BIOLOGICAL INORGANIC CHEMISTRY, 2000, 5 (03) :333-340