Flow injection fluorimetric method for the determination of ranitidine in pharmaceutical preparations using o-phthalaldehyde

被引:28
作者
LopezErroz, C [1 ]
Vinas, P [1 ]
Campillo, N [1 ]
HernandezCordoba, M [1 ]
机构
[1] UNIV MURCIA,FAC CHEM,DEPT ANALYT CHEM,E-30071 MURCIA,SPAIN
关键词
flow injection; fluorimetry; ranitidine; pharmaceuticals;
D O I
10.1039/an9962101043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection-fluorimetric procedure for the determination of ranitidine is proposed. The assay is based on the reaction of the drug with sodium hypochlorite, to produce a primary amine, which reacts with o-phthalaldehyde and 2-mercaptoethanol to form highly fluorescent derivatives, The calibration graph, based on peak area, is linear in the range 20-500 ng ml(-1) of ranitidine with an accuracy of 3.4%. The corresponding detection limit is 13 ng ml(-1) (3.7 pmol). The method was applied to the determination of ranitidine in pharmaceuticals. The recovery was quantitative and no interferences from excipients were observed.
引用
收藏
页码:1043 / 1046
页数:4
相关论文
共 34 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RANITIDINE IN HUMAN PLASMA [J].
ALKHAMIS, KI ;
ELSAYED, YM ;
ALRASHOOD, KA ;
BAWAZIR, SA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (02) :277-286
[2]   A SELECTIVE POSTCOLUMN "ORTHO-PHTHALALDEHYDE-DERIVATIZATION SYSTEM FOR THE DETERMINATION OF HISTAMINE IN BIOLOGICAL-MATERIAL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALLENMARK, S ;
BERGSTROM, S ;
ENERBACK, L .
ANALYTICAL BIOCHEMISTRY, 1985, 144 (01) :98-103
[3]  
[Anonymous], 1985, PHARM BASIS THERAPEU
[4]  
ARAFAT T, 1990, ALEXANDRIA J PHARM S, V4, P11
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF RANITIDINE AND RELATED SUBSTANCES IN RAW-MATERIALS AND TABLETS [J].
BEAULIEU, N ;
LACROIX, PM ;
SEARS, RW ;
LOVERING, EG .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1988, 77 (10) :889-892
[6]  
BOUTAGY J, 1984, J LIQ CHROMATOGR, V7, P1651, DOI 10.1080/01483918408074073
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF RANITIDINE IN PLASMA [J].
CAREY, PF ;
MARTIN, LE .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1979, 2 (09) :1291-1303
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF RANITIDINE AND ITS METABOLITES IN BIOLOGICAL-FLUIDS [J].
CAREY, PF ;
MARTIN, LE ;
EVANS, MB .
CHROMATOGRAPHIA, 1984, 19 :200-205
[9]  
CAREY PF, 1981, J CHROMATOGR-BIOMED, V14, P161
[10]  
DASGUPTA V, 1988, DRUG DEV IND PHARM, V14, P1647