Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report

被引:68
作者
Callaghan, JJ
O'Rourke, MR
Iossi, MF
Liu, SS
Goetz, DD
Vittetoe, DA
Sullivan, PM
Johnston, RC
机构
[1] Univ Iowa, Coll Med, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
[2] Iowa Methodist Hosp, Des Moines, IA USA
关键词
D O I
10.2106/JBJS.D.03039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We previously evaluated 119 consecutive total knee arthroplasties that were performed in eighty-six patients with use of the cemented LCS (low contact stress) rotating-platform system with an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years (range, thirty-seven to eighty-eight years). The purpose of this study was to report the updated results at a minimum follow-up of fifteen years. Thirty-seven patients (fifty-three knees) were living, and no patient was lost to follow-up. No knee was revised because of loosening, osteolysis, or wear. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. Osteolysis was present in three knees. No knee had radiographic signs of component loosening, and there were no dislocated bearings. The average range of motion was from 10 of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49, respectively, at the preoperative evaluation and 85 and 58 at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of fifteen years. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1995 / 1998
页数:4
相关论文
共 18 条
[1]   POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[2]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[3]  
Bellamy N, 1995, W ONTARIO MCMASTER U, P14
[4]  
BERT JM, 1990, CLIN ORTHOP RELAT R, P211
[5]  
Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
[6]  
BUECHEL FF, 1990, CLIN ORTHOP RELAT R, P162
[7]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[8]   Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[9]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
[10]   Knees long-term results of Kinematic Condylar knee replacement - An analysis of 404 knees [J].
Gill, GS ;
Joshi, AB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03) :355-358