Surface plasmon resonance analysis of staphylococcal enterotoxin B in food

被引:84
作者
Rasooly, A [1 ]
机构
[1] US FDA, Div Microbiol Studies, Washington, DC 20204 USA
关键词
D O I
10.4315/0362-028X-64.1.37
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Surface plasmon resonance (SPR) biosensors are electro-optical instruments used for analyzing real-time protein-protein interactions. This work evaluates an SPR biosensor (Biacore 3000) in the detection of staphylococcal enterotoxin B (SEB) in foods. A sandwich SPR immunosensor involving two antibodies was used. The capturing antibody, bound covalently to the surface of the biosensor chip, performs the initial binding of the antigen and a second antibody binds to the captured antigen. The second antibody makes antigen verification possible and amplifies the signal. Pure SEE as well as SEE in spiked foods (milk and meat) were detected with Little interference from the food matrix. Ln the control experiments with uncontaminated food samples no significant signal was detected. The SPR biosensor assay detects SEE at similar to 10 ng/ml rapidly, with initial binding within 2 min. The entire measurement cycle (including washing and chip regeneration) may take 5 min using one antibody or 8 min using two antibodies. These results suggest that the SPR biosensor may be a useful tool for real-time analysis of toxin in foods.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 34 条
  • [1] ARCHER D L, 1988, Clinical Microbiology Reviews, V1, P377
  • [2] Staphylococcus aureus:: A well-armed pathogen
    Archer, GL
    [J]. CLINICAL INFECTIOUS DISEASES, 1998, 26 (05) : 1179 - 1181
  • [3] Bergdoll MS, 1996, ADV EXP MED BIOL, V391, P465
  • [4] BERGER M, 1967, BIBL GYNAECOL, P1
  • [5] BETLEY MJ, 1984, P NATL ACAD SCI-BIOL, V81, P5179, DOI 10.1073/pnas.81.16.5179
  • [6] STAPHYLOCOCCAL ENTEROTOXIN-A IS ENCODED BY PHAGE
    BETLEY, MJ
    MEKALANOS, JJ
    [J]. SCIENCE, 1985, 229 (4709) : 185 - 187
  • [7] BETLEY MJ, 1986, ANNU REV MICROBIOL, V40, P577, DOI 10.1146/annurev.mi.40.100186.003045
  • [8] DETECTION OF RECEPTOR LIGAND INTERACTIONS USING SURFACE-PLASMON RESONANCE - MODEL STUDIES EMPLOYING THE HIV-1 GP120/CD4 INTERACTION
    BRIGHAMBURKE, M
    EDWARDS, JR
    OSHANNESSY, DJ
    [J]. ANALYTICAL BIOCHEMISTRY, 1992, 205 (01) : 125 - 131
  • [9] Piezoelectric immunosensor for the detection of immunoglobulin M
    Chu, X
    Lin, ZH
    Shen, GL
    Yu, RQ
    [J]. ANALYST, 1995, 120 (12) : 2829 - 2832
  • [10] ESTIMATION OF HUMAN DOSE OF STAPHYLOCOCCAL ENTEROTOXIN-A FROM A LARGE OUTBREAK OF STAPHYLOCOCCAL FOOD POISONING INVOLVING CHOCOLATE MILK
    EVENSON, ML
    HINDS, MW
    BERNSTEIN, RS
    BERGDOLL, MS
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1988, 7 (04) : 311 - 316