Biosensors based on aligned carbon nanotubes coated with inherently conducting polymers

被引:176
作者
Gao, M
Dai, LM
Wallace, GG
机构
[1] Univ Wollongong, Intelligent Polymer Res Inst, Wollongong, NSW 2522, Australia
[2] CSIRO, Div Mol Sci, Clayton, Vic 3169, Australia
关键词
aligned carbon nanotubcs; glucose oxidase; hydrogen peroxide; PULSED-AMPEROMETRIC DETECTION; PATTERNED GROWTH; ELECTRODES; POLYPYRROLE; ACTUATORS;
D O I
10.1002/elan.200390131
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ne use of multiwalled aligned carbon nanotubes provides a novel electrode platform for inherently conducting polymer based biosensors. The example used here to highlight the usefulness of such a platform is the polypyrrole based glucose oxidase system for detection of glucose. The use of these three dimensional electrodes offers advantages in that large accessible enzyme loadings can be obtained within an ultrathin layer. It has also been found that the detection of H2O2 at these new electrode structures containing iron loaded nanotube tips can be achieved at low anodic potentials. The result is a sensitive and selective glucose sensor.
引用
收藏
页码:1089 / 1094
页数:6
相关论文
共 25 条
  • [1] Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole-urease biosensor
    Adeloju, SB
    Shaw, SJ
    Wallace, GG
    [J]. ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) : 155 - 160
  • [2] POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION
    ADELOJU, SB
    SHAW, SJ
    WALLACE, GG
    [J]. ELECTROANALYSIS, 1994, 6 (10) : 865 - 870
  • [3] Electrochemical characterization of single-walled carbon nanotube electrodes
    Barisci, JN
    Wallace, GG
    Baughman, RH
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (12) : 4580 - 4583
  • [4] Electrochemical studies of single-wall carbon nanotubes in aqueous solutions
    Barisci, JN
    Wallace, GG
    Baughman, RH
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 488 (02): : 92 - 98
  • [5] Carbon nanotube actuators
    Baughman, RH
    Cui, CX
    Zakhidov, AA
    Iqbal, Z
    Barisci, JN
    Spinks, GM
    Wallace, GG
    Mazzoldi, A
    De Rossi, D
    Rinzler, AG
    Jaschinski, O
    Roth, S
    Kertesz, M
    [J]. SCIENCE, 1999, 284 (5418) : 1340 - 1344
  • [6] Carbon nanotube electrode for oxidation of dopamine
    Britto, PJ
    Santhanam, KSV
    Ajayan, PM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01): : 121 - 125
  • [7] Campbell TE, 1999, ELECTROANAL, V11, P215, DOI 10.1002/(SICI)1521-4109(199904)11:4<215::AID-ELAN215>3.0.CO
  • [8] 2-#
  • [9] Electrophoresis deposition of carbon nanotubes for triode-type field emission display
    Choi, WB
    Jin, YW
    Kim, HY
    Lee, SJ
    Yun, MJ
    Kang, JH
    Choi, YS
    Park, NS
    Lee, NS
    Kim, JM
    [J]. APPLIED PHYSICS LETTERS, 2001, 78 (11) : 1547 - 1549
  • [10] Protein electrochemistry at carbon nanotube electrodes
    Davis, Jason J.
    Coles, Richard J.
    Hill, H.Allen O.
    [J]. 1997, Elsevier Science S.A., Lausanne, Switzerland (440): : 1 - 2