A method for determination of ion distribution within electrosprayed droplets

被引:26
作者
Sjöberg, PJR [1 ]
Bökman, CF [1 ]
Bylund, D [1 ]
Markides, KE [1 ]
机构
[1] Uppsala Univ, Dept Analyt Chem, SE-75121 Uppsala, Sweden
关键词
D O I
10.1021/ac000759t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simplified method for determination of ion distribution within electrospray ionization droplets has been developed, The method is based on an electrospray ionization mass spectrometry equilibrium partitioning model recently developed by Enke (Enke, C. G, Anal. Chem. 1997, 69, 4885-4893). This "simple" method required only two samples to be analyzed at each solution composition compared to the method previously reported. Furthermore, as the same m/z value is monitored in both experiments, possible effects of the mass-dependent ion transmission in the quadrupole were eliminated. Tetraalkylammonium compounds with variable hydrophobicity were used as model compounds and the effect of methanol-water composition in the electrosprayed solution was studied. It was found, as expected, that the signal optimized at a high content of methanol in the electrosprayed solution. The distribution coefficient for analyte ions between the droplet surface and bulk solution maximize, however, at a lower content of methanol in the electrosprayed solution.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 46 条
[1]  
ALEXANDROV ML, 1984, DOKL AKAD NAUK SSSR+, V277, P379
[2]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[3]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[4]  
BRUINS AP, 1997, ELECTROSPRAY MASS SP, pCH3
[5]  
Cole R.B., 1997, Electrospray Ionization Mass Spectrometry
[6]   SOLVENT EFFECT ON ANALYTE CHARGE-STATE, SIGNAL INTENSITY, AND STABILITY IN NEGATIVE-ION ELECTROSPRAY MASS-SPECTROMETRY - IMPLICATIONS FOR THE MECHANISM OF NEGATIVE-ION FORMATION [J].
COLE, RB ;
HARRATA, AK .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :546-556
[7]   Effects of salt concentration on analyte response using electrospray ionization mass spectrometry [J].
Constantopoulos, TL ;
Jackson, GS ;
Enke, CG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (07) :625-634
[8]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[9]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[10]   ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME [J].
FENN, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :524-535