Split-bolus MDCT urography with synchronous nephrographic and excretory phase enhancement

被引:131
作者
Chow, Lawrence C.
Kwan, Sharon W.
Olcott, Eric W.
Sommer, Graham
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[2] VA Palo Alto Hlth Care Syst, Dept Radiol, Palo Alto, CA USA
关键词
bladder; CT; kidney; ureter; urography;
D O I
10.2214/AJR.07.2288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our purpose was to evaluate the utility of CT urography performed using a split contrast bolus that yields synchronous nephrographic and excretory phase enhancement. MATERIALS AND METHODS. Five hundred consecutive patients referred for evaluation of possible urinary tract abnormalities (327 for painless hematuria) underwent CT urography with unenhanced scanning of the abdomen and pelvis and scanning during concurrent nephrographic and excretory phase enhancement produced by administration of a split contrast bolus. The enhanced abdomen scan was obtained with abdominal compression; the enhanced pelvis scan was obtained after release of compression. Findings from axial sections and coronal maximum intensity projections were correlated with clinical follow-up and, as available, with laboratory and other imaging studies including cystoscopy, ureteroscopy, urine cytology, surgery, and pathology. Follow-up management for each patient was determined by the clinical judgment of the referring physician. RESULTS. CT urography identified 100% of pathologically confirmed renal cell carcinomas (n = 10) and uroepithelial malignancies involving the renal collecting system or ureter (n = 8). An additional nine renal masses were identified for which no pathologic proof has yet been obtained, including eight subcentimeter solid renal masses and one multiloculated lesion. Fourteen of 19 confirmed cases of uroepithelial neoplasm involving the bladder were identified. CT urography yielded one false-positive for bladder tumor, two false-positives for ureteral tumor, and one patient with a bladder mass who refused further evaluation. CT urography yielded sensitivity and specificity of 100% and 99% and 74% and 99% and positive predictive value and negative predictive value of 80% and 100% and 93% and 99% for the renal collecting system and ureter and bladder, respectively. CT urography was ineffective in identifying 11 cases of noninfectious cystitis. CT urography also depicted numerous other congenital and acquired abnormalities of the urinary tract. CONCLUSION. Split-bolus MDCT urography detected all proven cases of tumors of the upper urinary tract, yielding high sensitivity and specificity. The split-bolus technique has the potential to reduce both radiation dose and the number of images generated by MDCT urography.
引用
收藏
页码:314 / 322
页数:9
相关论文
共 19 条
[11]   Image quality and dose comparison among screen-film, computed, and CT scanned projection radiography: Applications to CT urography [J].
McCollough, CH ;
Bruesewitz, MR ;
Vrtiska, TJ ;
King, BF ;
LeRoy, AJ ;
Quam, JP ;
Hattery, RR .
RADIOLOGY, 2001, 221 (02) :395-403
[12]   Excretory phase CT urography for opacification of the urinary collecting system [J].
McNicholas, MMJ ;
Raptopoulos, VD ;
Schwartz, RK ;
Sheiman, RG ;
Zormpala, A ;
Prassopoulos, PK ;
Ernst, RD ;
Pearlman, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1261-1267
[13]   Multi-detector row CT urography: Comparison of strategies for depicting the normal urinary collecting system [J].
McTavish, JD ;
Jinzaki, M ;
Zou, KH ;
Nawfel, RD ;
Silverman, SG .
RADIOLOGY, 2002, 225 (03) :783-790
[14]   Patient radiation dose at CT urography and conventional urography [J].
Nawfel, RD ;
Judy, PF ;
Schleipman, AR ;
Silverman, SG .
RADIOLOGY, 2004, 232 (01) :126-132
[15]   A comparison of noncontrast computerized tomography with excretory urography in the assessment of acute flank pain [J].
Niall, O ;
Russell, J ;
MacGregor, R ;
Duncan, H ;
Mullins, J .
JOURNAL OF UROLOGY, 1999, 161 (02) :534-537
[16]  
SAKET R, 2004, P SOC URORADIOLOGY, P44
[17]   ACUTE FLANK PAIN - COMPARISON OF NON-CONTRAST-ENHANCED CT AND INTRAVENOUS UROGRAPHY [J].
SMITH, RC ;
ROSENFIELD, AT ;
CHOE, KA ;
ESSENMACHER, KR ;
VERGA, M ;
GLICKMAN, MG ;
LANGE, RC .
RADIOLOGY, 1995, 194 (03) :789-794
[18]   Bladder tumor detection at virtual cytoscopy [J].
Song, JH ;
Francis, IR ;
Platt, JF ;
Cohan, RH ;
Mohsin, J ;
Kielb, SJ ;
Korobkin, M ;
Montie, JE .
RADIOLOGY, 2001, 218 (01) :95-100
[19]   Virtual cystoscopy in the evaluation of bladder tumors [J].
Yazgan, C ;
Fitoz, S ;
Atasoy, C ;
Turkolmez, K ;
Yagci, C ;
Akyar, S .
CLINICAL IMAGING, 2004, 28 (02) :138-142