The impact of physiological motion on tissue tracking during radiation force imaging

被引:47
作者
Fahey, Brian J.
Palmeri, Mark L.
Trahey, Gregg E.
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27708 USA
关键词
ultrasound; ultrasonic imaging; acoustic radiation force; abdominal imaging; elastography; physiological motion; RADIOFREQUENCY ABLATION; THERMAL LESIONS; ELASTOGRAPHY; LIVER; DISPLACEMENTS; SPECKLE; ELASTICITY; PERFORMANCE;
D O I
10.1016/j.ultrasmedbio.2007.01.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effect of physiological motion on the quality of radiation force elasticity images has been investigated. Experimental studies and simulated images were used to investigate the impact of motion effects on image quality metrics over a range of clinically realistic velocity and acceleration magnitudes. Evaluation criteria included motion filter effectiveness, image signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of a stiff inclusion embedded in a homogeneous background material. Two transmit frequencies (2.5 and 4.4 MHz) were analyzed and contrasted in terms of image quality over a range of target motions. Results indicate that situations may exist where liver and cardiac motion magnitudes lead to poor image quality, but optimized transducer orientations may help suppress motion artifacts if some a priori information concerning target motion characteristics is known. In the presence of significant target motion, utilizing a lower transmit frequency can improve SNR and CNR in elasticity images. (E-mail: brian.fahey@duke.edu). (C) 2007 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1149 / 1166
页数:18
相关论文
共 40 条
[1]  
Anderson W.A. D., 1953, PATHOLOGY
[2]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[3]   The combined effect of signal decorrelation and random noise on the variance of time delay estimation [J].
Cespedes, I ;
Ophir, J ;
Alam, SK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :220-225
[4]   Elastographic image quality vs. tissue motion in vivo [J].
Chandrasekhar, R. ;
Ophir, J. ;
Krouskop, T. ;
Ophir, K. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (06) :847-855
[5]   2-D companding for noise reduction in strain imaging [J].
Chaturvedi, P ;
Insana, MF ;
Hall, TJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :179-191
[6]   Non-invasive assessment of ventricular force-frequency relations in the univentricular circulation by tissue Doppler echocardiography: a novel method of assessing myocardial performance in congenital heart disease [J].
Cheung, MMH ;
Smallhorn, JF ;
McCrindle, BW ;
Van Arsdell, GS ;
Redington, AN .
HEART, 2005, 91 (10) :1338-1342
[7]   Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment:: Initial comparison with MRI [J].
Curiel, L ;
Souchon, R ;
Rouvière, O ;
Gelet, A ;
Chapelon, JY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11) :1461-1468
[8]   Two-dimensional ultrasonic strain rate measurement of the human heart in vivo [J].
D'hooge, J ;
Konofagou, E ;
Jamal, F ;
Heimdal, A ;
Barrios, L ;
Bijnens, B ;
Thoen, J ;
Van de Werf, F ;
Sutherland, G ;
Suetens, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) :281-286
[9]  
DAHL JJ, IN PRESS IEEE T ULTR
[10]   Liver ablation guidance with acoustic radiation force impulse imaging: challenges and opportunities [J].
Fahey, B. J. ;
Hsu, S. J. ;
Wolf, P. D. ;
Nelson, R. C. ;
Trahey, G. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (15) :3785-3808