Liver ablation guidance with acoustic radiation force impulse imaging: challenges and opportunities

被引:63
作者
Fahey, B. J. [1 ]
Hsu, S. J.
Wolf, P. D.
Nelson, R. C.
Trahey, G. E.
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC USA
[2] Duke Univ, Ctr Med, Dept Radiol, Durham, NC USA
关键词
D O I
10.1088/0031-9155/51/15/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Previous studies have established the feasibility of monitoring radiofrequency (RF) ablation procedures with acoustic radiation force impulse (ARFI) imaging. However, questions remained regarding the utility of the technique in clinically realistic scenarios and at scanning depths associated with abdominal imaging in adults. We address several of these issues and detail recent progress towards the clinical relevance of the ARFI technique. Results from in vitro bovine tissues and an in vivo ovine model are presented. Additional experiments were conducted with a tissue-mimicking phantom and parallel receive tracking techniques in order to further support the clinical feasibility of the method. Thermal lesions created during RF ablation are visualized with high contrast in both in vitro and in vivo hepatic tissues, and radial lesion growth can be monitored throughout the duration of the procedure. ARFI imaging is implemented on a diagnostic ultrasonic scanner, and thus may be a convenient option to guide RF ablation procedures, particularly when electrode insertion is also performed with sonographic guidance.
引用
收藏
页码:3785 / 3808
页数:24
相关论文
共 48 条
[1]
FDG positron emission tomography in the surveillance of hepatic tumors treated with radiofrequency ablation [J].
Anderson, GS ;
Brinkmann, F ;
Soulen, MC ;
Alavi, A ;
Zhuang, HM .
CLINICAL NUCLEAR MEDICINE, 2003, 28 (03) :192-197
[2]
Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation [J].
Bharat, S ;
Techavipoo, U ;
Kiss, MZ ;
Liu, W ;
Varghese, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) :415-422
[3]
CT versus sonography for monitoring radiofrequency ablation in a porcine liver [J].
Cha, CH ;
Lee, FT ;
Gurney, JM ;
Markhardt, BK ;
Warner, TF ;
Kelcz, F ;
Mahvi, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :705-711
[4]
Early assessment of the therapeutic response to radio frequency ablation for hepatocellular carcinoma - Utility of gray scale harmonic ultrasonography with a microbubble contrast agent [J].
Choi, D ;
Lim, HK ;
Lee, WJ ;
Kim, SH ;
Kim, YH ;
Kim, SH ;
Lim, JH .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (11) :1163-1172
[5]
DAHL JJ, 2005, ULTRASONIC IMAGING, V26, P259
[6]
DAHL JJ, UNPUB IEEE T ULTR FE
[7]
Radiofrequency thermal ablation: Computer analysis of the size of the thermal injury created by overlapping ablations [J].
Dodd, GD ;
Frank, MS ;
Aribandi, M ;
Chopra, S ;
Chintapalli, KN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) :777-782
[8]
Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough [J].
Dodd, GD ;
Soulen, MC ;
Kane, RA ;
Livraghi, T ;
Lees, WR ;
Yamashita, Y ;
Gillams, AR ;
Karahan, OI ;
Rhim, H .
RADIOGRAPHICS, 2000, 20 (01) :9-27
[9]
[F-18] fluorodeoxyglucose positron emission tomography as a tool for early recognition of incomplete tumor destruction after radiofrequency ablation for liver metastases [J].
Donckier, V ;
Van Laethem, JL ;
Goldman, S ;
Van Gansbeke, D ;
Feron, P ;
Ickx, B ;
Wikler, D ;
Gelin, M .
JOURNAL OF SURGICAL ONCOLOGY, 2003, 84 (04) :215-223
[10]
Acoustic radiation force impulse imaging of the abdomen: Demonstration of feasibility and utility [J].
Fahey, BJ ;
Nightingale, KR ;
Nelson, RC ;
Palmeri, ML ;
Trahey, GE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) :1185-1198