SERS-based sandwich immunoassay using antibody coated magnetic nanoparticles for Escherichia coli enumeration

被引:182
作者
Guven, Burcu [1 ]
Basaran-Akgul, Nese [1 ]
Temur, Erhan [2 ]
Tamer, Ugur [2 ]
Boyaci, Ismail Hakki [1 ]
机构
[1] Hacettepe Univ, Fac Engn, Dept Food Engn, TR-06800 Beytepe, Turkey
[2] Gazi Univ, Fac Pharm, Dept Analyt Chem, TR-06330 Ankara, Turkey
关键词
ENHANCED RAMAN-SCATTERING; LABELED IMMUNOGOLD NANOPARTICLES; SURFACE-PLASMON RESONANCE; RAPID DETECTION; IMMUNOMAGNETIC SEPARATION; SILVER NANOPARTICLES; PATHOGEN DETECTION; WATER SAMPLES; FOOD SAMPLES; GROUND-BEEF;
D O I
10.1039/c0an00473a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method combining immunomagnetic separation (IMS) and surface-enhanced Raman scattering (SERS) was developed to enumerate Escherichia coli (E. coli). Gold-coated magnetic spherical nanoparticles were prepared by immobilizing biotin-labeled anti-E. coli antibodies onto avidin-coated magnetic nanoparticles and used in the separation and concentration of the E. coli cells. Raman labels have been constructed using rod shaped gold nanoparticles coated with 5,5-dithiobis-(2-nitrobenzoic acid) (DTNB) and subsequently with a molecular recognizer. Then DTNB-labeled gold nanorods were interacted with gold-coated magnetic spherical nanoparticle-antibody-E. coli complex. The capture efficiency and calibration graphs were obtained and examined in different E. coli concentrations (10(1)-10(7) cfu mL(-1)). The correlation between the concentration of bacteria and SERS signal was found to be linear within the range of 10(1)-10(4) cfu mL(-1) (R-2 = 0.992). The limit of detection (LOD) and limit of quantification (LOQ) values of the developed method were found to be 8 and 24 cfu mL(-1), respectively. The selectivity of the developed immunoassay was examined with Enterobacter aerogenes, Enterobacter dissolvens, and Salmonella enteriditis which did not produce any significant response. The ability of the immunoassay to detect E. coli in real water samples was also investigated and the results were compared with the experimental results from plate-counting methods. There was no significant difference between the methods that were compared (p > 0.05). This method is rapid and sensitive to target organisms with a total analysis time of less than 70 min.
引用
收藏
页码:740 / 748
页数:9
相关论文
共 55 条
[1]   Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7 [J].
Abdel-Hamid, I ;
Ivnitski, D ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) :309-316
[2]   Comparison of fluorogenic and chromogenic assay systems in the detection of Escherichia coli O157 by a novel polymyxin-based ELISA [J].
Blais, BW ;
Leggate, J ;
Bosley, J ;
Martinez-Perez, A .
LETTERS IN APPLIED MICROBIOLOGY, 2004, 39 (06) :516-522
[3]   Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads [J].
Boyaci, IH ;
Aguilar, ZP ;
Hossain, M ;
Halsall, HB ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) :1234-1241
[4]   Multiplex identification of bacteria in bacterial mixtures with surface-enhanced Raman scattering [J].
Cam, Dilek ;
Keseroglu, Kemal ;
Kahraman, Mehmet ;
Sahin, Fikrettin ;
Culha, Mustafa .
JOURNAL OF RAMAN SPECTROSCOPY, 2010, 41 (05) :484-489
[5]   Immunoassay using surface-enhanced Raman scattering based on aggregation of reporter-labeled immunogold nanoparticles [J].
Chen, Ji-Wei ;
Lei, Yong ;
Liu, Xiang-Jiang ;
Jiang, Jian-Hui ;
Shen, Guo-Li ;
Yu, Ru-Qin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (1-2) :187-193
[6]   Combining biofunctional magnetic nanoparticles and ATP bioluminescence for rapid detection of Escherichia coli [J].
Cheng, Yuxiao ;
Liu, Yajun ;
Huang, Jingjing ;
Li, Kang ;
Zhang, Wen ;
Xian, Yuezhong ;
Jin, Litong .
TALANTA, 2009, 77 (04) :1332-1336
[7]   Characterization of Thermophilic Bacteria Using Surface-Enhanced Raman Scattering [J].
Culha, Mustafa ;
Adiguzel, Ahmet ;
Yazici, M. Muege ;
Kahraman, Mehmet ;
Sahin, Fikrettin ;
Gulluce, Medine .
APPLIED SPECTROSCOPY, 2008, 62 (11) :1226-1232
[8]   PCR-ELISA detection of Escherichia coli in milk [J].
Daly, P ;
Collier, T ;
Doyle, S .
LETTERS IN APPLIED MICROBIOLOGY, 2002, 34 (03) :222-226
[9]   Determination of viable Escherichia coli using antibody-coated paramagnetic beads with fluorescence detection [J].
Dudak, F. Ceyda ;
Boyaci, Ismail H. ;
Jurkevica, Agnese ;
Hossain, Mahmud ;
Aquilar, Zoraida ;
Halsall, H. Brian ;
Seliskar, Carl J. ;
Heineman, William R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (03) :949-956
[10]   Enumeration of immunomagnetically captured Escherichia coli in water samples using quantum dot-labeled antibodies [J].
Dudak, Fahriye Ceyda ;
Boyaci, Ismail Hakki .
JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2008, 16 (02) :122-131