Gadolinium-DTPA and gadodiamide as an alternative contrast medium for CT.

被引:15
作者
Engelbrecht, V
Koch, JA
Rassek, M
Modder, U
机构
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1996年 / 165卷 / 01期
关键词
CT; gadolinium-DTPA; gadodiamid; contrast media;
D O I
10.1055/s-2007-1015709
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effect of intravenously applied gadolinium-based contrast medium in computed tomographic (CT) studies. Material and methods: Serial dilutions of iohexol 300, Gd-DTPA and gadodiamide were scanned with CT in a phantom study using water filled tubes. For quantification of x-ray attenuation, the mean Hounsfield units (HU) were calculated from the CT scans. Five patients with contraindications against iodine contrast agents were examined with abdominal or thoracic CT before and after application of 0.2 mmol/kg body weight of a gadolinium-based contrast agent. In these patients attenuation values were obtained in ROI from unenhanced and enhanced CT scans. Results: The phantom study revealed a 38.4% enhancement for Gd-DTPA and a 35.7% enhancement for gadodiamide scaled on the reference measurements with iohexol 300. Thus, 130.2 ml Gd-DTPA or 140.1 ml gadodiamide are needed to achieve the same attenuation as an i.v. injection of 50 ml iohexol 300. Consequently the corresponding dose of 1 mmol/kg body weight would exceed the manufacturer's recommended dose. In four patients with complete thoracic or abdominal CT, i.v. applied gadolinium-based contrast medium (0.2 mmol/kg) yielded no visible advantage. In these patients parenchymal enhancement did not exceed 25%. Dynamic CT of a patient with focal liver lesion revealed an arterial enhancement peak of 75%. Conclusion: Sufficient parenchymal enhancement in CT studies cannot be achieved with the available gadolinium-based contrast mediums. They might be helpful if only short time vascular enhancement is required.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 10 条
[1]   GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[2]   QUANTITATIVE CT APPLICATIONS - COMPARISON OF CURRENT SCANNERS [J].
CANN, CE .
RADIOLOGY, 1987, 162 (01) :257-261
[3]   EXPERIMENTAL AND THEORETICAL X-RAY-IMAGING PERFORMANCE COMPARISON OF IODINE AND LANTHANIDE CONTRAST AGENTS [J].
CARDINAL, HN ;
HOLDSWORTH, DW ;
DRANGOVA, M ;
HOBBS, BB ;
FENSTER, A .
MEDICAL PHYSICS, 1993, 20 (01) :15-31
[4]  
DEAN PB, 1984, HDB EXPT PHARM, V73, P479
[5]   AN ASSESSMENT OF GD-DTPA AS A CT CONTRAST AGENT IN THE RENAL TRACT [J].
GIBSON, RJ ;
MEANOCK, CI ;
TORRIE, EPH ;
WALKER, TM .
CLINICAL RADIOLOGY, 1993, 47 (04) :278-279
[6]  
GMELIN E, 1985, Roentgen-Blaetter, V38, P219
[7]  
HENDEE WR, 1983, PHYSICAL PRINCIPLES, P101
[8]   GD-DTPA - AN ALTERNATIVE CONTRAST-MEDIUM FOR CT [J].
QUINN, AD ;
OHARE, NJ ;
WALLIS, FJ ;
WILSON, GF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :634-636
[9]   GADOLINIUM-DTPA (MAGNEVIST) AS A CONTRAST-MEDIUM FOR ARTERIAL DSA [J].
SCHILD, HH ;
WEBER, W ;
BOECK, E ;
MILDENBERGER, P ;
STRUNK, H ;
DUBER, C ;
GREBE, P ;
SCHADMANDFISCHER, S ;
THELEN, M .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (03) :218-221
[10]   CONTRAST OPACIFICATION FOR CT FROM IODINE, GADOLINIUM AND YTTERBIUM - INVITRO AND ANIMAL-EXPERIMENTS [J].
ZWICKER, C ;
LANGER, M ;
URICH, V ;
FELIX, R .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (03) :255-259