Electrical field interactions in different cochlear implant systems

被引:71
作者
Boëx, C [1 ]
de Balthasar, C [1 ]
Kós, MI [1 ]
Pelizzone, M [1 ]
机构
[1] Univ Hosp, Ctr Romand Implants Cochleaires, CH-1211 Geneva 14, Switzerland
关键词
D O I
10.1121/1.1610451
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The goal of this study was to evaluate electrical field interactions produced by the stimulation of different types of intracochlear electrodes in 12 adult subjects (three Ineraid(TM), four Clarion(TM) S-Series, three S-Series with the electrode positioning system-EPS and two Clarion(TM) HiFocus-I with the EPS). Psychophysical measurements were conducted with biphasic stimuli (813 pulse per second, 153.8 mus/phase). "Perturbation" signals (300 ms) were applied to one electrode chosen at the middle of the array and their effects on detection thresholds of "probe" signals (30 ms) were measured on the neighbor basal electrode. Perturbation levels were set below the detection threshold of the perturbation electrode (-2 dB re threshold). Measurements were first conducted for simultaneous stimulation of the probe and of the perturbation electrodes, for monopolar for all subjects and for bipolar stimulus configurations for both Clarion(TM) HiFocus-I subjects. The tested Clarion(TM) electrodes did not present lower monopolar interactions than the Ineraid(TM) electrodes. Nevertheless, considering the shorter distance between electrodes for the Clarion(TM) than for the Ineraid(TM), the tested Clarion(TM) electrodes might be more selective than the Ineraid(TM). We did not find any significant monopolar electrical field-interaction differences between subjects who received the S-Series array with and without the EPS. We did not find lower interactions for both subjects who received the HiFocus-I array than for subjects who received the S-Series. Electrical field interactions were lower for bipolar than for monopolar configurations for both HiFocus-I subjects. A second set of measurements was conducted for nonsimultaneous stimulation similar to the one used in continuous interleaved sampling sound strategy. These measurements showed that interactions evaluated for simultaneous biphasic stimuli were larger than for nonsimultaneous stimulation. (C) 2003 Acoustical Society of America.
引用
收藏
页码:2049 / 2057
页数:9
相关论文
共 45 条
[1]   Simultaneous Analog Stimulation (SAS) Continuous Interleaved Sampler (CIS) pilot comparison study in Europe [J].
Battmer, RD ;
Zilberman, Y ;
Haake, P ;
Lenarz, T .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) :69-73
[2]   Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration [J].
Bierer, JA ;
Middlebrooks, JC .
JOURNAL OF NEUROPHYSIOLOGY, 2002, 87 (01) :478-492
[3]   DIFFERENTIAL ELECTRICAL EXCITATION OF THE AUDITORY-NERVE [J].
BLACK, RC ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 67 (03) :868-874
[4]   Forward masking in different cochlear implant systems [J].
Boëx, C ;
Kós, MI ;
Pelizzone, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 114 (04) :2058-2065
[5]   Electrically evoked whole nerve action potentials in ineraid cochlear implant users: Responses to different stimulating electrode configurations and comparison to psychophysical responses [J].
Brown, CJ ;
Abbas, PJ ;
Borland, J ;
Bertschy, MR .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (03) :453-467
[6]   PITCH PERCEPTION FOR DIFFERENT MODES OF STIMULATION USING THE COCHLEAR MULTIPLE-ELECTRODE PROSTHESIS [J].
BUSBY, PA ;
WHITFORD, LA ;
BLAMEY, PJ ;
RICHARDSON, LM ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (05) :2658-2669
[7]   Psychophysics of a prototype peri-modiolar cochlear implant electrode array [J].
Cohen, LT ;
Saunders, E ;
Clark, GM .
HEARING RESEARCH, 2001, 155 (1-2) :63-81
[8]   Channel interactions with high-rate biphasic electrical stimulation in cochlear implant subjects [J].
de Balthasar, C ;
Boëx, C ;
Cosendai, G ;
Valentini, G ;
Sigrist, A ;
Pelizzone, M .
HEARING RESEARCH, 2003, 182 (1-2) :77-87
[9]   Electrical and physiological changes during short-term and chronic electrical stimulation of the normal cochlea [J].
deSauvage, RC ;
daCosta, DL ;
Erre, JP ;
Aran, JM .
HEARING RESEARCH, 1997, 110 (1-2) :119-134
[10]   Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants [J].
Donaldson, GS ;
Peters, MD ;
Ellis, MR ;
Friedman, BJ ;
Levine, SC ;
Rimell, FL .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2001, 127 (08) :956-960