Sensitive voltammetric response of methylparathion on single-walled carbon nanotube paste coated electrodes using ionic liquid as binder

被引:69
作者
Fan, Shuangshuang [1 ,2 ]
Xiao, Fei [1 ]
Liu, Liqin [1 ]
Zhao, Faqiong [1 ]
Zeng, Baizhao [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Chengde Teachers Coll Natl, Chengde 067000, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2008年 / 132卷 / 01期
关键词
methylparathion; p-nitrophenol; ionic liquid; single-walled carbon nanotubes; glassy carbon electrode; voltammetry;
D O I
10.1016/j.snb.2008.01.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ionic liquid (i.e. 1-butyl-3-methylimidazolium hexafluophosphate, BMIMPF6)-single-walled carbon nanotube (SWNT) paste coated glassy carbon electrode (BMIMPF6-SWNT/GCE) has been fabricated. The electrode shows good electro-catalysis to the reduction of methylparathion (NIP) and MP can accumulate effectively on it. Thus, MP can produce a sensitive cathodic peak on the BMIMPF6-SWNT/GCE. Parameters influencing the voltammetric response of MP are optimized for MP determination. Under the selected experimental conditions (i.e. solution pH 7.0; accumulation time, 180 s; accumulation potential, on open-circuit; the ratio of SWNT to BMIMPF6 1:20 (mg mu L-1)), the peak current is linear to; concentration over the range of 2.0 x 10(-9) to 4.0 x 10(-6) M. The detection limit is 1.0 x 10(-9) M. Therefore, this system is quite sensitive in comparison with other electrochemical methods. In addition, it is found that the hydrolysate of MP (i.e. p-nitrophenol, PNP) can also produce a sensitive cathodic peak under this condition. But the peaks of MP and PNP do not overlap with each other. Hence they can be determined simultaneously. This electrode has been applied to the determination of MP and PNP in real samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 39
页数:6
相关论文
共 19 条
[1]   Simultaneous optimization by neuro-genetic approach of a multiresidue method for determination of pesticides in Passiflora alata infuses using headspace solid phase microextraction and gas chromatography [J].
da Silva, Gilmare Antonia ;
Augusto, Fabio ;
Poppi, Ronei Jesus .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) :251-261
[2]   Molecular ordering of organic molten salts triggered by single-walled carbon nanotubes [J].
Fukushima, T ;
Kosaka, A ;
Ishimura, Y ;
Yamamoto, T ;
Takigawa, T ;
Ishii, N ;
Aida, T .
SCIENCE, 2003, 300 (5628) :2072-2074
[3]   VOLTAMMETRIC DETERMINATION OF METHYL PARATHION, ORTHO, META AND PARA NITROPHENOL WITH A CARBON PASTE ELECTRODE MODIFIED WITH C-18 [J].
HERNANDEZ, L ;
HERNANDEZ, P ;
VICENTE, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (11) :712-715
[4]   α-chymotrypsin catalysis in imidazolium-based ionic liquids [J].
Laszlo, JA ;
Compton, DL .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (02) :181-186
[5]   Direct electrochemistry of glucose oxidase entrapped in nano gold particles-ionic liquid-N,N-dimethylformamide composite film on glassy carbon electrode and glucose sensing [J].
Li, Jiangwen ;
Yu, Jingjing ;
Zhao, Faqiong ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :33-40
[6]   Characterization of a graphite powder-ionic liquid paste coated gold electrode, and a method for voltammetric determination of promethazine [J].
Li, Jiangwen ;
Zhao, Faqiong ;
Zeng, Baizhao .
MICROCHIMICA ACTA, 2007, 157 (1-2) :27-33
[7]   An in situ STM study on the long-range surface restructuring of Au(111) in a non-chloroaluminumated ionic liquid [J].
Lin, LG ;
Wang, Y ;
Yan, JW ;
Yuan, YZ ;
Xiang, J ;
Mao, BW .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (12) :995-999
[8]   An ionic liquid-type carbon paste polyoxometalate-modified electrode and its properties [J].
Liu, HT ;
He, P ;
Li, ZY ;
Sun, CY ;
Shi, LH ;
Liu, Y ;
Zhu, GY ;
Li, JH .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) :1357-1363
[9]   Analytical applications of room-temperature ionic liquids: A review of recent efforts [J].
Pandey, S .
ANALYTICA CHIMICA ACTA, 2006, 556 (01) :38-45
[10]   High-performance liquid chromatographic assay of phosphate and organophosphorus pesticides using a post-column photochemical reaction and fluorimetric detection [J].
Pérez-Ruiz, T ;
Martínez-Lozano, C ;
Tomás, V ;
Martín, J .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :383-391