Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging

被引:468
作者
Breuer, FA [1 ]
Blaimer, M [1 ]
Heidemann, RM [1 ]
Mueller, MF [1 ]
Griswold, MA [1 ]
Jakob, PM [1 ]
机构
[1] Univ Wurzburg, Dept Phys, D-97074 Wurzburg, Germany
关键词
parallel imaging; SENSE; GRAPPA; multi-slice; controlled aliasing;
D O I
10.1002/mrm.20401
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In all current parallel imaging techniques, aliasing artifacts resulting from an undersampled acquisition are removed by means of a specialized image reconstruction algorithm. In this study a new approach termed "controlled aliasing in parallel imaging results in higher acceleration" (CAIPIRINHA) is presented. This technique modifies the appearance of aliasing artifacts during the acquisition to improve the subsequent parallel image reconstruction procedure. This new parallel multi-slice technique is more efficient compared to other multi-slice parallel imaging concepts that use only a pure postprocessing approach. In this new approach, multiple slices of arbitrary thickness and distance are excited simultaneously with the use of multi-band radiofrequency (RF) pulses similar to Hadamard pulses. These data are then undersampled, yielding superimposed slices that appear shifted with respect to each other. The shift of the aliased slices is controlled by modulating the phase of the individual slices in the multi-band excitation pulse from echo to echo. We show that the reconstruction quality of the aliased slices is better using this shift. This may potentially allow one to use higher acceleration factors than are used in techniques without this excitation scheme. Additionally, slices that have essentially the same coil sensitivity profiles can be separated with this technique.
引用
收藏
页码:684 / 691
页数:8
相关论文
共 20 条
[1]  
BLAIMER M, 2003, P 20 ANN M ESMRMB RO, P109
[2]  
Breuer F, 2004, P 12 ANN M ISMRM KYO, P326
[3]  
Cunningham CH, 1999, MAGNET RESON MED, V42, P577, DOI 10.1002/(SICI)1522-2594(199909)42:3<577::AID-MRM21>3.0.CO
[4]  
2-E
[5]   PHASE-OFFSET MULTIPLANAR (POMP) VOLUME IMAGING - A NEW TECHNIQUE [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04) :457-461
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[8]  
2-5
[9]   VD-AUTO-SMASH imaging [J].
Heidemann, RM ;
Griswold, MA ;
Haase, A ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1066-1074
[10]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42