Hydrodynamics-induced variability in the USP apparatus II dissolution test

被引:99
作者
Baxter, JL [1 ]
Kukura, J [1 ]
Muzzio, FJ [1 ]
机构
[1] Rutgers State Univ, Dept Chem & Biochem Engn, Piscataway, NJ 08854 USA
关键词
dissolution testing; hydrodynamics; USP apparatus II; shear; computational fluid dynamics;
D O I
10.1016/j.ijpharm.2004.08.003
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The USP tablet dissolution test is an analytical tool used for the verification of drug release processes and formulation selection within the pharmaceutical industry. Given the strong impact of this test, it is surprising that operating conditions and testing devices have been selected empirically. In fact, the flow phenomena in the USP test have received little attention in the past. An examination of the hydrodynamics in the USP apparatus II shows that the device is highly vulnerable to mixing problems that can affect testing performance and consistency. Experimental and computational techniques reveal that the flow field within the device is not uniform, and dissolution results can vary dramatically with the position of the tablet within the vessel. Specifically, computations predict sharp variations in the shear along the bottom of the vessel where the tablet is most likely to settle. Experiments in which the tablet location was carefully controlled reveal that the variation of shear within the testing device can affect the measured dissolution rate. (c) 2004 Published by Elsevier B.V.
引用
收藏
页码:17 / 28
页数:12
相关论文
共 25 条
[11]   Measurement of agitation force in dissolution test and mechanical destructive force in disintegration test [J].
Kamba, M ;
Seta, Y ;
Takeda, N ;
Hamaura, T ;
Kusai, A ;
Nakane, H ;
Nishimura, K .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2003, 250 (01) :99-109
[12]  
Kresta S. M., 2004, HDB IND MIXING SCI P
[13]   Engineering tools for understanding the hydrodynamics of dissolution tests [J].
Kukura, J ;
Arratia, PE ;
Szalai, ES ;
Muzzio, FJ .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2003, 29 (02) :231-+
[14]  
Kukura J., 2002, PHARM TECHN, V26, P48
[15]   DEVELOPMENT OF IN VITRO DISSOLUTION TESTS WHICH CORRELATE QUANTITATIVELY WITH DISSOLUTION RATE-LIMITED DRUG ABSORPTION IN MAN [J].
LEVY, G ;
LEONARDS, JR ;
PROCKNAL, JA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1965, 54 (12) :1719-&
[17]  
MAUGER JW, 1996, DISSOLUTION TECHNOLO, V3, P7
[18]  
Moore J.W., 1996, PHARM TECHNOL, V20, P64, DOI DOI 10.1017/CCOL521633230.011
[19]  
MOORE TW, 1995, PHARMACOPEIAL FORUM, V21, P1387
[20]   Cause of high variability in drug dissolution testing and its impact on setting tolerances [J].
Qureshi, SA ;
Shabnam, J .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2001, 12 (03) :271-276