摘要
A method to determine depth of interaction (DOI) from a PET detector module is described and evaluated. The basic element of the DOI detector module is a two crystal detector unit. The hypothesis is that by controlling how light is shared between two crystals (A and B) DOI information can be extracted from the ratio of light collected using simple Anger type logic [A/(A+B)]. The interface between crystals is designed so that a significant amount of light is shared when a photon interacts near the front face of a crystal and very little light is shared when an interaction occurs near the back of a crystal. The effects of surface treatment (e.g., polished, roughened) and optical coupling compounds are investigated. EGO, GSO and LSO detector units have been evaluated. A DOI uncertainty; of similar to 6mm was attained for the front section (similar to 4mm) of a 2x2x20mm LSO detector unit. A method to decode a 64 crystal detector module (32 detector units) using a 16 channel multi-anode photomultiplier tube is described.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 14 条
[1]  
ANGER HO, 1967, INSTRUM NUCL, V1, pCH19
[2]   A DEPTH-ENCODED PET DETECTOR [J].
BARTZAKOS, P ;
THOMPSON, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :732-738
[3]   INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET [J].
DERENZO, SE ;
MOSES, WW ;
JACKSON, HG ;
TURKO, BT ;
CAHOON, JL ;
GEYER, AB ;
VULETICH, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1084-1089
[5]   CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR [J].
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :502-505
[6]   A METHOD FOR CORRECTING THE DEPTH-OF-INTERACTION BLURRING IN PET CAMERAS [J].
ROGERS, JG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :146-150
[7]   DESIGN OF A VOLUME-IMAGING POSITRON EMISSION TOMOGRAPH [J].
ROGERS, JG ;
HARROP, R ;
COOMBES, GH ;
WILKINSON, NA ;
ATKINS, MS ;
PATE, BD ;
MORRISON, KS ;
STAZYK, M ;
DYKSTRA, CJ ;
BARNEY, JS ;
DOHERTY, PW ;
SAYLOR, DP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :993-997
[8]  
Shao YP, 1996, IEEE T NUCL SCI, V43, P1938
[9]   DEVELOPMENT OF 3-D DETECTOR SYSTEM FOR POSITRON CT [J].
SHIMIZU, K ;
OHMURA, T ;
WATANABE, M ;
UCHIDA, H ;
YAMASHITA, T .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :717-720
[10]   CERIUM-ACTIVATED GD2SIO5 SINGLE-CRYSTAL SCINTILLATOR [J].
TAKAGI, K ;
FUKAZAWA, T .
APPLIED PHYSICS LETTERS, 1983, 42 (01) :43-45