Force track analysis of contemporary hip simulators

被引:31
作者
Calonius, O [1 ]
Saikko, V [1 ]
机构
[1] Helsinki Univ Technol, Dept Mech Engn, FIN-02015 Helsinki, Finland
基金
芬兰科学院;
关键词
force track; slide track; hip simulator; direction of sliding; wear;
D O I
10.1016/S0021-9290(03)00166-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
In an earlier paper, the authors presented the first verified method of computation of slide tracks in the relative motion between femoral head and acetabular cup of total hip prostheses. The method was applied for gait and for two hip simulator designs, and in a subsequent paper, for another eight designs. In the present paper, the track drawn by the resultant contact force, the so-called force track, was studied in depth. The variations of sliding distance, sliding velocity and direction of sliding during a cycle, all of which are important with respect to wear, were computed for gait and for 11 hip simulator designs. Moreover, the product of the instantaneous load and increment of sliding distance was numerically integrated over a cycle. This integral makes it possible to compare clinical wear rates with those produced by hip simulators in terms of a wear factor. For the majority of contemporary hip simulators, the integral has so far been unknown. The computations revealed considerable differences, which are likely to explain the substantial differences in wear produced by the simulators. With the most common head diameter, 28 mm, the ranges for sliding distance per cycle, mean sliding velocity, total change of direction of sliding and integral were: 19.7-34.3 mm, 19.7-49.0 mm/s, 360-1513degrees, and 17.4-43.5 N m, respectively. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1719 / 1726
页数:8
相关论文
共 17 条
[1]
LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .3. THE MEASUREMENT OF INTERNAL VOLUME CHANGES IN EXPLANTED CHARNLEY SOCKETS AFTER 2-16 YEARS INVIVO AND THE DETERMINATION OF WEAR FACTORS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, JH ;
WROBLEWSKI, BM .
WEAR, 1985, 104 (03) :225-244
[2]
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[3]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[4]
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[5]
Slide track analysis of eight contemporary hip simulator designs [J].
Calonius, O ;
Saikko, V .
JOURNAL OF BIOMECHANICS, 2002, 35 (11) :1439-1450
[6]
Dowson D, 1988, Eng Med, V17, P111, DOI 10.1243/EMED_JOUR_1988_017_031_02
[7]
A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints [J].
Goldsmith, AAJ ;
Dowson, D .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) :77-90
[8]
*ISO DIS, 2001, 142421 ISODIS 1
[9]
MEASUREMENT OF HIP-JOINT MOTION DURING WALKING - EVALUATION OF AN ELECTROGONIOMETRIC METHOD [J].
JOHNSTON, RC ;
SMIDT, GL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1969, A 51 (06) :1083-&
[10]
McKellop H. A., 1985, ASTM STP, P351