A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates

被引:108
作者
Barbour, PSM [1 ]
Stone, MH
Fisher, J
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Gen Infirm, Leeds LS1 3EX, W Yorkshire, England
关键词
total hip replacement; wear; polyethylene; wear simulator;
D O I
10.1243/0954411991535068
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In some designs of hip joint simulator the cost of building a highly complex machine has been offset with the requirement for a large number of test stations. The application of the wear results generated by these machines depends on their ability to reproduce physiological wear rates and processes. In this study a hip joint simulator has been shown to reproduce physiological wear using only one load vector and two degrees of motion with simplified input cycles. The actual path of points on the femoral head relative to the acetabular cup were calculated and compared for physiological and simplified input cycles. The in vitro wear rates were found to be highly dependent on the shape of these paths and similarities could be drawn between the shape of the physiological paths and the simplified elliptical paths.
引用
收藏
页码:455 / 467
页数:13
相关论文
共 38 条
[1]   LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .3. THE MEASUREMENT OF INTERNAL VOLUME CHANGES IN EXPLANTED CHARNLEY SOCKETS AFTER 2-16 YEARS INVIVO AND THE DETERMINATION OF WEAR FACTORS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, JH ;
WROBLEWSKI, BM .
WEAR, 1985, 104 (03) :225-244
[2]  
BESONG AA, 1997, P WORLD TRIB C LOND, P732
[3]   Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant [J].
Bigsby, RJA ;
Hardaker, CS ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :265-269
[4]  
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[5]  
Campbell P, 1996, Proc Inst Mech Eng H, V210, P167, DOI 10.1243/PIME_PROC_1996_210_409_02
[6]  
CHARNLEY J, 1975, CLIN ORTHOP RELAT R, P170
[7]  
Clarke I., 1989, PROGR BIOENGINEERING, P104
[8]  
Clarke IC, 1981, ENG MED, V10, P189
[9]  
Cooper J. R., 1993, Clinical Materials, V14, P295, DOI 10.1016/0267-6605(93)90016-Z
[10]   COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236